HDL36100 SQUARE D, HDL36100 Datasheet - Page 42

CIRCUIT BREAKER, THERMAL MAG, 3P, 100A

HDL36100

Manufacturer Part Number
HDL36100
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 100A
Manufacturer
SQUARE D
Series
PowerPactr
Type
Standardr
Datasheets

Specifications of HDL36100

Actuator Style
Toggle
No. Of Poles
3
Current Rating
100A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Actuator Type
Handle
Brand/series
HD Series
Characteristic
Adjustable Trip
Dimensions
6.40 (H) × 4.12 (W) × 4.36 (D) in.
Frame Type
H
Number Of Poles
3
Terminal Type
Line: Lug - Load: Lug
Voltage Rating
600/250 VAC/DC
Weight
5.00 lbs.
Wire Size
#14-3/0 AWG (Al/Cu)
Ampere Interrupting Ratings
25 k @ 240 VAC, 18k @ 480 VAC
Standards
UL489, CSA, NOM, IEC 60947, CE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
42
PowerPact
Section 3—Accessories
Table 56:
Table 57:
1
2
3
4
5
6
HDL,HGL,HJL,HLL
JDL,JGL,JJL,JLL
HDL
JDL
1.00 MIN
[25,4]
Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require
field cut opening. For details and hub catalog numbers see Digest 174 page 3-9.
Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall.
Copper wire only
Maximum short circuit rating is 25 kAIR, 240 Vac
Order service ground kit PKOGTA2 if required.
Maximum short circuit rating is 18 kAIR, 480 Vac.
Cat. No. Prefix
06/2010
h
Circuit Breaker
Enclosure Dimensions
Circuit Breaker Enclosure Catalog Numbers
®
H- and J-Frame Circuit Breakers
h
15–150 A
150–250 A
15–100 A
150–250 A
Rating
Variable Depth Mechanisms
Designed for installation in custom built control enclosures where main or branch circuit protective
devices are required.
Circuit Breaker Enclosures and Enclosure Accessories
All circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting,
convertible on the job.
Variable mounting depth range: 5.88–17.75 in. (149–451 mm).
Operating mechanism 9422RQ1 (does not include handle mechanism).
Square D circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as
service entrance equipment, except as footnoted.
The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker
installed, except as footnoted.
Circuit breakers are ordered and shipped separately for field installation.
2, 3
2, 3
3
3
1.00 MIN
[25,4]
Poles
4.00 MIN
[101,6]
4.00 MIN
[101,6]
J250F
NEMA 1
Flush
00 MIN
d
J250S
HD100S
JD250S
NEMA 1
Surface
3, 5, 6
3, 4, 5
Circuit
Breaker
H-Frame
J-Frame
J250R
NEMA
3R
1
Amperage
15–150 A
150–250 A
Enclosure Cat. No.
J250DS
NEMA 4, 4X, 5, 3, 3R
Stainless Steel
Enclosure Dimensions (h x w x d)
80%
18.13 x 8.63 x 4.13 in.
(461 x 219 x 105 mm)
28.5 x 12.38 x 5.38 in.
(724 x 314 x 137 mm)
© 2004–2010 Schneider Electric
J250AWK
(Without Knockouts)
100%
62 x 14 x 22.5 in.
(572 x 356 x 1575 mm)
62 x 14 x 22.6 in.
(572 x 356 x 1575 mm)
NEMA 12/3R, 5
All Rights Reserved
2

Related parts for HDL36100