38
SPECIAL I/O MODULES
MIXED I/O MODULE
Specifications
Note:
MODULE NAME
PART NUMBER
Inputs
Outputs
External connection
Internal current consumption (5 VDC)
Manual
C200H-MD215/MD115
(16 DC input/16 transistor output pts.)
C200H-MD501
(16 TTL input/16 TTL output pts.)
When mounting any of the above models to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-RM201.
No. of inputs
Input voltage and current
Operating voltages
Input response times
Isolations
Inputs per common
No. of outputs
Rated load voltage
Max. load current
Residual voltage
Output response times
Leakage current
Outputs per common
Fuse
TTL INPUT/OUTPUT MODULE
C200H-MD501
16 pts
5 VDC 10%, 3.5 mA (5 VDC)
ON: 3.0 V min., OFF: 1.0 V max.
ON/OFF: 2.5 ms/15 ms (selectable)
Photocoupler
8 pts
16 pts
5 VDC
35 mA/pt, 280 mA/8 pts
0.4 V max.
ON: 0.2 ms max., OFF: 0.3 ms max.
0.1 mA max.
8 pts
Present (replacement not possible)
Connector
180 mA max.
W302
The high-density/multiplex mixed Input/Output modules let you
pack more I/O points into a single I/O slot for greater space sav-
ings. Treated as Special I/O modules, they do not use standard
I/O points. Thus, they increase the overall I/O capacity.
In static high-density mode, they provide 16 discrete input
points and 16 discrete output points with selectable input
response times of 2.5 ms or 15 ms. For even shorter input
signals, 8 inputs can be designated as quick-response inputs, to
receive selectable 1 ms or 4 ms signals. In this mode, the
modules can also be used with Omron’s Terminal Blocks,
reducing wiring between control panels as well as within control
panels.
In dynamic multiplex input mode, the modules provide 128
dynamic input points. In this mode they can be used with
keyboards, thumbwheel switches, etc.
Features
DC INPUT/TRANSISTOR OUTPUT MODULE
C200H-MD215
24 VDC +10%--15%, 4.1 mA
(24 VDC)
ON: 14.4 V min., OFF: 5.0 V max.
5 to 24 VDC
100 mA/pt, 800 mA/8 pts
0.7 V max.
ON: 0.2 ms max., OFF: 0.6 ms max.
Provide 16 inputs and 16 outputs per module in static mode;
128 inputs in dynamic mode
Easy cable connection to Omron’s XW2B-
using XW2Z-
Parts section for detailed ordering information.
Selectable input response time
Up to 10 Special I/O modules per PLC
Provide interface to keyboards, thumbwheel switches, etc. in
dynamic mode

Connecting Cable. Refer to the Standard
C200H-MD115
12 VDC +10%--15%, 4.1 mA typical
(12 VDC)
ON: 8.0 V min., OFF: 3.0 V max.
12 VDC
100 mA/pt, 800 mA/8 pts

Terminal Blocks