Specifications of CQM1H-CTB41

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
I/O Word Allocation
Module type
Input module
Output modules
B7A Master
li k
link modules
DeviceNet I/O link module
Profibus-DP
I/O link
module
AS-Interface
master module
CompoBus/S
master
modules
Analog input module
Analog output module
Analog power supply modules for
CQM1-AD041 and -DA021
Temperature
control
modules
Safety relay module
A--168
/O
as e
as e
d l
d l
d l
odu e
Programmable Controller
B7A02
B7A12
B7A03
B7A13
B7A21
IN: 32 points
OUT: 32 points
IN: 64 points
OUT: 64 points
IN: 96 points
OUT: 96 points
IN: 128 points
OUT: 128 points
IN: 44 points
OUT: 44 points
IN: 60 points
OUT: 60 points
IN: 92 points
OUT: 92 points
IN: 76 points
OUT: 76 points
IN: 92 points
OUT: 92 points
IN: 124 points
OUT: 124 points
IN:16 points
OUT: 16 points
IN: 32 points
OUT: 32 points
IN: 64 points
OUT: 64 points
00j/10j
20j/30j
I/O word allocation
Input
words
1 or 2
1
2
1
1
2
4
6
8
3
4
6
5
6
8
1
2
4
2 or 4
2 or 1
1
1
CQM1H
Output
words
1 or 2
1
1
1
1
2
4
6
8
3
4
6
5
6
8
1
2
4
2
2 or 1
1
Description
Each 8-point or 16-point input module is allocated one input word and each
32-point input module is allocated two input words. Words will be allocated in
order starting from IR 001.
Each 8-point or 16-point output module is allocated one output word and
each 32-point output module is allocated two output words. Words will be
allocated in order starting from IR 100.
Depending on the module, each B7A Master link module is allocated input
words and output words.
Each DeviceNet I/O link module is allocated one input word and one output
word.
The Profibus-DP master configuration data must match this setting.
This setting will influence the maximum number of AS-Interface slaves that
can be addressed by the PLC.
ca be add essed by
Depending on the module, each CompoBus/S master module is allocated
input words and output words.
Each analog input module can be set to input either 2 or 4 points. If the mod-
ule is set to input 2 points, two input words are allocated. If the module is set
to input 4 points, four input words are allocated.
Each analog output module is allocated two output words.
Power supply modules are not involved directly in I/O operations and are thus
not allocated I/O words.
Each temperature control module is allocated two input words and two output
words when two loops are used. Only one input word and one output word
are allocated when one loop is used.
One input word and one output word are allocated in the order the module is
connected.
One input word is allocated per module in the order the module is connected.
pu
p
d
o ds a d ou pu
d
g
t
t
d
e
o ds
,
C
p

Related parts for CQM1H-CTB41