UDA1341TSDB NXP Semiconductors, UDA1341TSDB Datasheet - Page 20

Audio CODECs AUDIO CODEC MINIDISC

UDA1341TSDB

Manufacturer Part Number
UDA1341TSDB
Description
Audio CODECs AUDIO CODEC MINIDISC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of UDA1341TSDB

Number Of Adc Inputs
4
Number Of Dac Outputs
2
Conversion Rate
48 KSPs
Interface Type
Serial (I2S), L3
Resolution
20 bit
Operating Supply Voltage
2.4 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SSOP-28
Minimum Operating Temperature
- 20 C
Number Of Channels
2
Snr
100 dB
Supply Current
12.5 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
UDA1341TS/N1,512
NXP Semiconductors
7.21.3.3
A 2-bit value to program the mode of the digital mixer.
There are four modes: double differential, input channel 1
select, input channel 2 select and digital mixer mode.
The default setting is given in Table 5.
Table 28 Mixer mode switch settings
7.21.3.4
A 1-bit value to enable the AGC input. The default setting
is given in Table 5.
Table 29 AGC control settings
7.21.3.5
A 2-bit value to program the AGC output level. The default
setting is given in Table 5.
Table 30 AGC output level settings
2002 May 16
MM1 MM0
AL1
Economy audio CODEC for MiniDisc (MD)
home stereo and portable applications
0
0
1
1
0
0
1
1
AG
0
1
AL0
0
1
0
1
0
1
0
1
Mixer mode
AGC control
AGC output level
double differential mode
input channel 1 select (input channel 2 off)
input channel 2 select (input channel 1 off)
digital mixer mode
(input 1 × MA + input 2 × MB)
disable AGC: manual gain setting through
IG (7 bits)
enable AGC: gain control with manual MIC
sensitivity setting
−15.0
−17.5
−11.5
−9.0
OUTPUT LEVEL
FUNCTION
FUNCTION
(dB FS)
20
7.21.3.6
A 7-bit value to program the input channel 2 amplifier gain.
The range is from −3 to +60.5 dB in steps of 0.5 dB. These
settings are only valid when AGC control is disabled and
not valid in the double differential mode.
Table 31 Input channel 2 amplifier gain settings
7.21.3.7
A 3-bit value to program the attack and the decay
parameters of the digital AGC. The default setting is given
in Table 5.
Table 32 AGC time constant settings
IG6 IG5 IG4 IG3 IG2 IG1 IG0
AT2
0
0
0
0
0
0
0
1
1
1
:
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
:
AT1
0
0
1
1
0
0
1
1
Input channel 2 amplifier gain
AGC time constant
0
0
0
0
0
0
0
1
1
1
:
AT0
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
1
1
1
:
ATTACK TIME
0
0
0
0
1
1
1
1
1
1
:
(ms)
11
16
11
16
21
11
16
21
0
0
1
1
0
0
1
0
1
1
:
0
1
0
1
0
1
0
1
0
1
UDA1341TS
:
Product specification
DECAY TIME
CHANNEL 2
AMPLIFIER
−3.0
−2.5
−2.0
−1.5
−1.0
−0.5
59.5
60.0
60.5
INPUT
GAIN
0.0
(ms)
(dB)
100
100
200
200
200
400
400
400
:

Related parts for UDA1341TSDB