XR16L2450IJ-F Exar Corporation, XR16L2450IJ-F Datasheet - Page 18

no-image

XR16L2450IJ-F

Manufacturer Part Number
XR16L2450IJ-F
Description
2.25 To 5.5V W/ 5V TOLERANT DUART
Manufacturer
Exar Corporation
Datasheet

Specifications of XR16L2450IJ-F

Features
*
Number Of Channels
2, DUART
Fifo's
1 Byte
Protocol
RS232
Voltage - Supply
2.25 V ~ 5.5 V
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Package / Case
44-LCC (J-Lead)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L2450IJ-F
Manufacturer:
Exar Corporation
Quantity:
10 000
XR16L2450
2.25V TO 5.5V DUART
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Flag
LSR[3]: Receive Data Framing Error Flag
LSR[4]: Receive Break Flag
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. This bit indicates that the transmitter is ready to
accept a new character for transmission. In addition, this bit causes the UART to issue an interrupt to the host
when the THR interrupt enable is set. The THR bit is set to a logic 1 when the data byte is transferred from the
transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data
loading to the transmit holding register by the host.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character.
LSR[7]: Reserved
This register provides the current state of the modem interface signals, or other peripheral device that the
UART is connected. Lower four bits of this register are used to indicate the changed information. These bits
are set to a logic 1 whenever a signal from the modem changes state. These bits may be used as general
purpose inputs/outputs when they are not used with modem signals.
MSR[0]: Delta CTS# Input Flag
4.8
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while there is data in the RHR. In this case the previous data in the receive shift
register is overwritten. Note that under this condition the data byte in the receive shift register is not
transferred into the RHR, therefore the data in the RHR is not corrupted by the error. An interrupt will be
generated immediately if LSR interrupt is enabled (IER bit-2).
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR. If the LSR interrupt is enabled (IER
bit-2), an interrupt will be generated when the character is in the RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR. If the LSR interrupt is enabled (IER bit-2), an interrupt will be
generated when the character is in the RHR.
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). The
break indication remains until the RX input returns to the idle condition, “mark” or logic 1. If the LSR interrupt
is enabled (IER bit-2), an interrupt will be generated when the character is in the RHR.
Logic 0 = No change on CTS# input (default).
Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
Modem Status Register (MSR) - Read Only
18
xr
REV. 1.1.1