ALXD800EEXJ2VD C3 AMD (ADVANCED MICRO DEVICES), ALXD800EEXJ2VD C3 Datasheet - Page 499

no-image

ALXD800EEXJ2VD C3

Manufacturer Part Number
ALXD800EEXJ2VD C3
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of ALXD800EEXJ2VD C3

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Video Input Port Register Descriptions
6.10.2.13 VIP Task A V Offset (VIP_TASK_A_V_OFFSET)
VIP Memory Offset 30h
Type
Reset Value
AMD Geode™ LX Processors Data Book
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
31:0
Bit
3:1
Bit
7
6
5
4
0
Name
EFD
TP
VP
HP
RSVD
FR
Name
TASK_A_V_
ODD_OFFSET
R/W
00000000h
VIP_CONTRL_REG3 Bit Descriptions (Continued)
Description
Even Field UV Decimation. When set to 1, the U and V values of the even frame will be
discarded.
Note:
Task Polarity. When set to 1, the input TASK bit is inverted.
VSYNC Polarity. This bit is set to 1 when the VSYNC input is active high (high during
VBLANK) or 0 when the VSYNC input is active low (low during VBLANK). This is only
used for 601 type input video where HSYNC and VSYNC signals are used rather then
the SAV/EAV codes.
HSYNC Polarity. This bit is set to 1 when the HSYNC input is active high (high during
HBLANK) or 0 when the HSYNC input is active low (low during HBLANK). This is only
used for 601 type input video where HSYNC and VSYNC signals are used rather then
the SAV/EAV codes.
Reserved.
FIFO Reset. Setting this bit forces the VIP FIFO pointers and data counts to their reset
state. This might be used in cases where high GLIU latencies cause continuous FIFO
overflows, when a line overrun error occurs, or if the line offset gets corrupted which
could result in an image shift. This bit remains a 1 during the FIFO reset sequence. When
the FIFO reset sequence has completed, this bit is automatically reset to a 0.
The FIFO reset sequence consists of:
Input reception is halted.
The input and output FIFO addresses and data counts are reset.
Wait for all outstanding GLIU requests to be completed.
The FIFO Reset bit is set to 0.
Input data reception starts after the programmed run control event has occurred (i.e.,
start of line, field, frame).
Description
Task A V Odd Offset. This register determines the starting address of the V buffer when
data is stored in planar format. The start of the V buffer is determined by adding the con-
tents of this register to that of the base address. This value must be 32-byte aligned. (Bits
[4:0] are required to be 00000.)
VIP_TASK_A_V_OFFSET Bit Descriptions
VIP_TASK_A_V_OFFSET Register Map
TASK_A_V_ODD_OFFSET
The DD bit (VIP Memory Offset 00h[16]) should be set to 1 or even lines will also
be decimated.
9
8
33234H
7
6
5
4
Program to 00000
3
2
1
499
0

Related parts for ALXD800EEXJ2VD C3