AD5173BRM2.5-RL7 Analog Devices Inc, AD5173BRM2.5-RL7 Datasheet - Page 19

IC DGTL POT DUAL 2.5K OTP 10MSOP

AD5173BRM2.5-RL7

Manufacturer Part Number
AD5173BRM2.5-RL7
Description
IC DGTL POT DUAL 2.5K OTP 10MSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5173BRM2.5-RL7

Rohs Status
RoHS non-compliant
Taps
256
Resistance (ohms)
2.5K
Number Of Circuits
2
Temperature Coefficient
35 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resistance In Ohms
2.5K
Number Of Elements
2
# Of Taps
256
Resistance (max)
2.5KOhm
Power Supply Requirement
Single
Interface Type
Serial (2-Wire/I2C)
Single Supply Voltage (typ)
3/5V
Dual Supply Voltage (typ)
Not RequiredV
Single Supply Voltage (min)
2.7V
Single Supply Voltage (max)
5.5V
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
10
Lead Free Status / RoHS Status
Not Compliant
I
WRITE MODE
Table 10. AD5172 Write Mode
Table 11. AD5173 Write Mode
READ MODE
Table 12. AD5172 Read Mode
Table 13. AD5173 Read Mode
Table 14. SDA Bits Descriptions
Bit
S
P
A
AD0, AD1
X
W
R
A0
SD
T
OW
D7, D6, D5, D4, D3, D2, D1, D0
E1, E0
2
S
S
S
S
C INTERFACE
0
0
0
0
1
1
1
1
Slave address byte
Slave address byte
Slave address byte
Slave address byte
0
0
0
0
1
1
1
1
1 AD1 AD0 W
1 AD1 AD0 R
1
1
1
1
1
1
W
Description
Start condition.
Stop condition.
Acknowledge.
Package pin-programmable address bits.
Don’t care.
Write.
Read.
RDAC subaddress select bit.
Shutdown connects wiper to B terminal and open circuits the A terminal. It does not change the
contents of the wiper register.
OTP programming bit. Logic 1 programs the wiper permanently.
Overwrites the fuse setting and programs the digital potentiometer to a different setting. Upon
power-up, the digital potentiometer is preset to either midscale or fuse setting, depending on
whether the fuse link was blown.
Data bits.
OTP validation bits.
00 = ready to program.
10 = fatal error. Some fuses not blown. Do not retry. Discard this unit.
11 = programmed successfully. No further adjustments are possible.
R
A
A D7 D6 D5 D4 D3 D2 D1 D0 A
A A0 SD
A D7 D6 D5 D4 D3 D2 D1 D0 A
A0 SD
Instruction byte
Instruction byte
T
Instruction byte
Instruction byte
T
Rev. H | Page 19 of 24
0 OW X
0 OW X
X
X
X
X
A
A D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0
E1 E0
E1 E0
X
X
Data byte
Data byte
Data byte
Data byte
X
X
X
X
AD5172/AD5173
X
X
X
X
X
X
A
A
A
A
P
P
P
P