CS43L22-CNZ Cirrus Logic Inc, CS43L22-CNZ Datasheet - Page 64

IC DAC W/HDPN & SPKR AMPS 40QFN

CS43L22-CNZ

Manufacturer Part Number
CS43L22-CNZ
Description
IC DAC W/HDPN & SPKR AMPS 40QFN
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS43L22-CNZ

Package / Case
40-QFN
Number Of Bits
24
Data Interface
Serial
Number Of Converters
1
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Conversion Rate
96 KSPS
Resolution
24 bit
Interface Type
Serial
Operating Supply Voltage
1.8 V or 2.5 V
Operating Temperature Range
+ 85 C
Mounting Style
SMD/SMT
Number Of Dac Outputs
2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1529 - BOARD EVAL FOR CS43L22
Power Dissipation (max)
-
Settling Time
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1650

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS43L22-CNZ
Manufacturer:
CRYSTAL
Quantity:
170
Part Number:
CS43L22-CNZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS43L22-CNZR
Manufacturer:
CIRRUSLOG
Quantity:
1 183
64
12.PARAMETER DEFINITIONS
Dynamic Range
Total Harmonic Distortion + Noise
Frequency Response
Interchannel Isolation
Interchannel Gain Mismatch
Gain Drift
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
bandwidth. Dynamic Range is a signal-to-noise ratio measurement over the specified band width made with
a -60 dBFS signal. 60 dB is added to resulting measurement to refer the measurement to full-scale. This
technique ensures that the distortion components are below the noise level and do not affect the measure-
ment. This measurement technique has been accepted by the Audio Engineering Society, AES17-1991,
and the Electronic Industries Association of Japan, EIAJ CP-307. Expressed in decibels.
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
band width (typically 10 Hz to 20 kHz), including distortion components. Expressed in decibels. Measured
at -1 and -20 dBFS as suggested in AES17-1991 Annex A.
A measure of the amplitude response variation from 10 Hz to 20 kHz relative to the amplitude response at
1 kHz. Units in decibels.
A measure of crosstalk between the left and right channel pairs. Measured for each channel at the convert-
er's output with no signal to the input under test and a full-scale signal applied to the other channel. Units in
decibels.
The gain difference between left and right channel pairs. Units in decibels.
The change in gain value with temperature. Units in ppm/°C.
Confidential Draft
3/4/10
CS43L22
DS792F2