EP1C3T144A8N Altera, EP1C3T144A8N Datasheet - Page 33

IC CYCLONE FPGA 2910 LE 144-TQFP

EP1C3T144A8N

Manufacturer Part Number
EP1C3T144A8N
Description
IC CYCLONE FPGA 2910 LE 144-TQFP
Manufacturer
Altera
Series
Cyclone®r
Datasheet

Specifications of EP1C3T144A8N

Number Of Logic Elements/cells
2910
Number Of Labs/clbs
291
Total Ram Bits
59904
Number Of I /o
104
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
144-TQFP, 144-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1C3T144A8N
Manufacturer:
ALTERA
Quantity:
248
Part Number:
EP1C3T144A8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1C3T144A8N
Manufacturer:
ALTERA
0
Part Number:
EP1C3T144A8N
Manufacturer:
ALTERA
Quantity:
20 000
Chapter 5: Cyclone II Devices
Power Analysis and Estimation
Power Analysis and Estimation
PowerPlay Early Power Estimator
PowerPlay Power Analyzer
© March 2010 Altera Corporation
f
1
1
Support for the automotive-grade Cyclone II devices is only available in the
Quartus II software version 7.2 SP1 and later.
Altera provides the following power analysis and estimation tools for your design:
The PowerPlay Early Power Estimator (EPE) is a power estimation tool that helps you
estimate the power consumption of your design during the system planning phase for
proper power supply planning and consideration. The EPE allows you to enter design
information based on architectural features and calculates the power consumed by
each architectural feature. Inputs to the EPE are environmental conditions and device
resources (such as clock frequency, RAM blocks, and DSP blocks) that you expect to
use in your design. The EPE then calculates the static and dynamic power, current
estimates, and thermal analysis for the design.
You can either enter the design information manually into the spreadsheet or import a
power estimator file of a fully or partially completed design from the Quartus II
software. After importing a file, you can edit some of the input parameters including
V
your system requirements.
The value obtained from the EPE is only an estimation and should not be used as a
specification. The accuracy of the EPE results is dependent on how close your input of
the design information into the EPE resembles that of the final design.
For more information about the EPE, and how to generate and import the power
estimator file, refer to the
FPGAs.
The PowerPlay Power Analyzer tool in the Quartus II software is a power analysis
tool that helps you calculate your design power consumption accurately to ensure
thermal and power supply budgets are not violated after your design is complete. The
PowerPlay Power Analyzer tool requires your design to be synthesized and fitted to
the target device. Availability of information such as design resources, how the
design is placed and routed on the target device, and the I/O standards assigned to
each I/O cell allow the PowerPlay Power Analyzer tool to provide accurate power
estimation.
The process of using the PowerPlay Power Analyzer tool consists of three parts:
specifying sources of input data, specifying operating conditions, and running the
PowerPlay Power Analyzer tool.
CCINT
“PowerPlay Early Power Estimator”
“PowerPlay Power Analyzer”
, ambient temperature, airflow, clock frequency, and toggle percentage to suit
PowerPlay Early Power Estimator User Guide for Cyclone II
The Automotive-Grade Device Handbook
5–3

Related parts for EP1C3T144A8N