SC18IM700IPW,112 NXP Semiconductors, SC18IM700IPW,112 Datasheet - Page 5

IC CTRL I2C W/UART 16-TSSOP

SC18IM700IPW,112

Manufacturer Part Number
SC18IM700IPW,112
Description
IC CTRL I2C W/UART 16-TSSOP
Manufacturer
NXP Semiconductors
Type
Master I2C bus controller with UART interfacer
Datasheet

Specifications of SC18IM700IPW,112

Package / Case
16-TSSOP
Controller Type
I²C Bus Controller
Interface
I²C, UART
Voltage - Supply
2.4 V ~ 3.6 V
Current - Supply
9mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Data Rate
9600 bit/s
Supply Voltage (max)
+ 5.5 V
Supply Voltage (min)
- 0.5 V
Supply Current
15 mA
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Mounting Style
SMD/SMT
Operating Supply Voltage
2.3 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-3512 - DEMO BOARD UART TO I2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-3231-5
935280629112
SC18IM700IPW

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC18IM700IPW,112
Manufacturer:
Renesas
Quantity:
51
NXP Semiconductors
SC18IM700_2
Product data sheet
7.1.2 Read N byte from slave device
7.1.3 Write to 18IM internal register
The host issues the read command by sending an S character followed by an I
slave device address, and the total number of bytes to be read from the addressed
I
command, the SC18IM700 will access the I
bytes from the addressed I
Note that the second byte sent is the I
bit (R) of this byte must be set to 1 to indicate this is an I
The host issues the internal register write command by sending a W character followed by
the register and data pair. Each register to be written must be followed by the data byte.
The frame is then terminated with a P character.
Remark: Write and read from the internal 18IM register is processed immediately as soon
as the intended register is determined by 18IM.
2
Fig 3. Write N bytes to slave device
Fig 4. Read N byte from slave device
Fig 5. Write to 18IM internal register
C-bus slave. The frame is then terminated with a P character. Once the host issues this
W CHAR.
host sends
S CHAR.
REGISTER 0
SLAVE ADR.
Rev. 02 — 10 August 2007
host sends
18IM responds
S CHAR.
+ W
2
DATA 0
C-bus slave, and then return the data to the host.
SLAVE ADR.
DATA 0
OF BYTES
NUMBER
2
+ R
C-bus device slave address. The least significant
Master I
DATA N
2
C-bus slave device, get the correct number of
DATA 0
OF BYTES
NUMBER
REGISTER N
2
C-bus controller with UART interface
2
C-bus write command.
P CHAR.
002aac049
DATA N
DATA N
SC18IM700
P CHAR.
002aac048
© NXP B.V. 2007. All rights reserved.
P CHAR.
002aac050
2
C-bus
5 of 22

Related parts for SC18IM700IPW,112