MPR083Q Freescale Semiconductor, MPR083Q Datasheet - Page 15

IC CTLR TOUCH SENSOR PROX 16-QFN

MPR083Q

Manufacturer Part Number
MPR083Q
Description
IC CTLR TOUCH SENSOR PROX 16-QFN
Manufacturer
Freescale Semiconductor
Type
Capacitiver
Datasheet

Specifications of MPR083Q

Number Of Inputs/keys
8 Slider
Data Interface
I²C, Serial
Voltage - Supply
1.8 V ~ 3.6 V
Current - Supply
1.62mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QFN Exposed Pad
Output Type
Voltage
Interface
I²C
Input Type
Logic
Supply Voltage
3.3 V
Dimensions
5 mm L x 5 mm W x 1 mm H
Supply Current
41µA
Ic Interface Type
I2C
Supply Voltage Range
1.8V To 3.6V
Sensor Case Style
QFN
No. Of Pins
16
Operating Temperature Range
-40°C To +85°C
Filter Terminals
SMD
Rohs Compliant
Yes
For Use With
DEMOMPR083 - BOARD DEMO FOR MPR083 CTLRKITMPR083EVM - KIT EVAL 8POSITION ROTARY TOUCH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR083Q
Manufacturer:
Freescale
Quantity:
2 494
Sensors
Freescale Semiconductor
5
5.1
The MPR083 features a Low Power mode that can reduce the power consumption into the microamps range. This feature can
be used to both adjust the response time of the system, and change the conditions on which Low Power would be enabled.
5.2
This Low Power configuration is only active when the sensor controller is in Run2 mode. The Low Power mode decreases current
consumption by increasing the response time of the MPR083. This increase is controlled through two factors.
During normal Run2 operation of the sensor controller the Max Response Time (MRT) is calculated by taking the product of the
TASP and the primary clock. From Chapter 4 the primary clock is the (MTP + 5) ms. Since the sensor controller is in Run2, the
primary clock is also multiplied by a factor of 8. The debounce rate of the MPR083 is 4 times the sample rate thus the MRT is
represented by the following equation.
First, the Idle Interface Timeout (IIT) represents the total time the touch interface should remain idle before going into Low Power
mode. This value can be calculated by taking the product of the ITP, TASP and primary clock (8ms) with a factor of 64. Thus the
IIT is represented as follows:
Second, the Max Response Time (MRT) represents the total time the touch interface should remain inactive before scanning the
electrodes. This value can be calculated by taking the product of the SCD, TASP and primary clock (8ms) with a factor of 5. Thus
the MRT is represented as follows:
When in Run2 mode, the sensor controller will initially scan the electrodes at the rate of MRT
touch interface remains idle for the IIT period then the scan period will change to MRT
detected the scan rate will transition back to MRT
Low Power Configuration
Introduction
Operation
MRT
run2 SET
ITT
MRT
2
=
=
Figure 18. Low Power Scan Period Transition Diagram
1
MTP
--------------------- -
=
MTP
--------------------- -
8
MTP
--------------------- -
8
+
+
5
8
5
1
+
+
.
+
LP DISABLED
1
5
1
MRT 1
+
1
TASP ITP
TASP SCD 4 8
TASP 4 8ms
TOUCH DETECTED
ITT PERIOD
6 8ms
 ms
2
. When scanning at MRT
MRT 2
1
. When scanning at MRT
2
and a touch is
Equation 1
Equation 2
Equation 3
1
MPR083
and the
15