PCA9543AD,118 NXP Semiconductors, PCA9543AD,118 Datasheet - Page 14

IC I2C SWITCH 2CH 14-SOIC

PCA9543AD,118

Manufacturer Part Number
PCA9543AD,118
Description
IC I2C SWITCH 2CH 14-SOIC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9543AD,118

Applications
2-Channel I²C Multiplexer
Interface
I²C, SMBus
Voltage - Supply
2.3 V ~ 5.5 V
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Mounting Type
Surface Mount
For Use With
OM6285 - EVAL BOARD I2C-2002-1A568-4002 - DEMO BOARD I2C568-3615 - DEMO BOARD I2C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-1857-2
935275803118
PCA9543AD-T
NXP Semiconductors
11. Dynamic characteristics
Table 9.
[1]
[2]
[3]
[4]
[5]
PCA9543A_43B_43C_6
Product data sheet
Symbol
t
f
t
t
t
t
t
t
t
t
t
t
C
t
t
t
INT
t
t
t
t
RESET
t
t
t
PD
SCL
BUF
HD;STA
LOW
HIGH
SU;STA
SU;STO
HD;DAT
SU;DAT
r
f
SP
VD;DAT
VD;ACK
v(INTnN-INTN)
d(INTnN-INTN)
w(rej)L
w(rej)H
w(rst)L
rst
REC;STA
b
Pass gate propagation delay is calculated from the 20
Hold time (repeated) START condition. After this period, the first clock pulse is generated.
A device must internally provide a hold time of at least 300 ns for the SDA signal (referred to the V
bridge the undefined region of the falling edge of SCL.
C
Measurements taken with 1 k pull-up resistor and 50 pF load.
b
= total capacitance of one bus line in pF.
Dynamic characteristics
Parameter
propagation delay
SCL clock frequency
bus free time between a STOP and
START condition
hold time (repeated) START condition
LOW period of the SCL clock
HIGH period of the SCL clock
set-up time for a repeated START
condition
set-up time for STOP condition
data hold time
data set-up time
rise time of both SDA and SCL
signals
fall time of both SDA and SCL signals
capacitive load for each bus line
pulse width of spikes that must be
suppressed by the input filter
data valid time
data valid acknowledge time
valid time from INTn to INT signal
delay time from INTn to INT inactive
LOW-level rejection time
HIGH-level rejection time
LOW-level reset time
reset time
recovery time to START condition
Rev. 06 — 15 June 2009
Conditions
from SDA to SDx,
or SCL to SCx
HIGH-to-LOW
LOW-to-HIGH
INTn inputs
INTn inputs
SDA clear
typical R
2-channel I
on
and the 15 pF load capacitance.
2
C-bus switch with interrupt logic and reset
[2]
[5]
[5]
PCA9543A/43B/43C
Standard-mode
Min
250
500
4.7
4.0
4.7
4.0
4.7
4.0
0
0.5
0
1
4
0
-
[3]
-
-
-
-
-
-
-
-
-
I
2
C-bus
0.3
1000
Max
3.45
100
300
400
0.6
50
1
1
4
2
-
-
-
-
-
-
-
-
-
-
-
-
IH(min)
[1]
of the SCL signal) in order to
Fast-mode I
20 + 0.1C
20 + 0.1C
Min
100
500
1.3
0.6
1.3
0.6
0.6
0.6
0
0.5
0
4
0
1
-
-
-
-
-
-
-
-
[3]
© NXP B.V. 2009. All rights reserved.
b
b
[4]
[4]
2
C-bus Unit
0.3
Max
400
300
300
400
0.9
0.6
50
1
1
4
2
-
-
-
-
-
-
-
-
-
-
-
-
[1]
14 of 23
ns
kHz
ns
ns
ns
pF
ns
ns
ns
ns
s
s
s
s
s
s
s
s
s
s
s
s
s
s

Related parts for PCA9543AD,118