TDA7563 STMicroelectronics, TDA7563 Datasheet - Page 11
TDA7563
Manufacturer Part Number
TDA7563
Description
IC AMP AUDIO 72W AB 27FLEXIWATT
Manufacturer
STMicroelectronics
Type
Class ABr
Datasheet
1.TDA7563.pdf
(20 pages)
Specifications of TDA7563
Output Type
4-Channel (Quad)
Max Output Power X Channels @ Load
72W x 4 @ 2 Ohm
Voltage - Supply
8 V ~ 18 V
Features
I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting Type
Through Hole
Package / Case
27-Flexiwatt (bent and staggered leads)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-2183-5
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA7563
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
TDA7563A
Manufacturer:
STMicroelectronics
Quantity:
135
Part Number:
TDA7563A
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563AEP
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563AH
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA7563B
Manufacturer:
ST
Quantity:
20 000
– To avoid momentary re-circulation spikes from giving erroneous diagnostics, a check of the output sta-
– Instead, if an overload is detected during the check after 1 ms, then a diagnostic cycle having a duration
– After a diagnostic cycle, the audio channel interested by the fault is switched to RESTART mode. The
– To check the status of the device a sampling system is needed. The timing is chosen at microprocessor
Figure 19. Restart timing without Diagnostic Enable (Permanent) - Each 1mS time, a sampling of
Figure 20. Restart timing with Diagnostic Enable (Permanent)
OUTPUT DC OFFSET DETECTION
Any DC output offset exceeding +/- 2 V are signalled out. This inconvenient might occur as a consequence of
initially defective or aged and worn-out input capacitors feeding a DC component to the inputs, so putting the
speakers at risk of overheating.
This diagnostic has to be performed with low-level output AC signal (or Vin = 0).
The test is run with selectable time duration by microprocessor (from a "start" to a "stop" command):
– START = Last reading operation or setting IB1 - D5 - (OFFSET enable) to 1
circuit protection intervention
circuit protection intervention
tus is made after 1ms: if normal situation (no overloads) is detected, the diagnostic is not performed and
the channel returns back active.
of about 100 ms is started.
relevant data are stored inside the device and can be read by the microprocessor. When one cycle has
terminated, the next one is activated by an I
throughout the car-radio operating time.
level (over half a second is recommended).
(i.e. short circuit to GND)
(i.e. short circuit to GND)
Overcurrent and short
Overcurrent and short
the fault is done
1-2mS
1-2mS
1mS
100/200mS
1mS
2
C reading. This is to ensure continuous diagnostics
1mS
1mS
Short circuit removed
1mS
1mS
t
Short circuit removed
t
TDA7563
Out
11/20