IC AMP AUDIO 150W AB 27FLEXIWATT

TDA7575

Manufacturer Part NumberTDA7575
DescriptionIC AMP AUDIO 150W AB 27FLEXIWATT
ManufacturerSTMicroelectronics
TypeClass AB
TDA7575 datasheets
 


Specifications of TDA7575

Output Type1-Channel (Mono) or 2-Channel (Stereo)Max Output Power X Channels @ Load150W x 1 @ 1 Ohm; 75W x 2 @ 2 Ohm
Voltage - Supply8 V ~ 18 VFeaturesDifferential Inputs, I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting TypeThrough HolePackage / Case27-Flexiwatt (bent and staggered leads)
Operational ClassClass-ABOutput Power (typ)150x1@1Ohm/75x2@2OhmW
Audio Amplifier FunctionSpeakerTotal Harmonic Distortion0.02@1Ohm@30W%
Single Supply Voltage (typ)9/12/15VDual Supply Voltage (typ)Not RequiredV
Power Supply RequirementSinglePower Dissipation86W
Rail/rail I/o TypeNoSingle Supply Voltage (min)8V
Single Supply Voltage (max)18VDual Supply Voltage (min)Not RequiredV
Dual Supply Voltage (max)Not RequiredVOperating Temp Range-55C to 150C
Operating Temperature ClassificationMilitaryMountingSurface Mount
Pin Count36Package TypePSOP
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
Page 14/21

Download datasheet (585Kb)Embed
PrevNext
DOCUMENT CD00003142
REVISION 3.0
TDA7575PD
If R/W = 1, the TDA7575PD sends 2 "Diagnostics Bytes" to µP: DB1 and DB2.
DB1
Thermal warming (if Tchip ≥ 150°C, D7 = 1)
D7
Diag. cycle not activated or not terminated (D6 = 0)
D6
Diag. cycle terminated (D6 = 1)
D5
X
Channel 1
D4
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
Channel 1
D3
Normal load (D3 = 0)
Short load (D3 = 1)
Channel 1
Turn-on diag.: No open load (D2 = 0)
D2
Offset diag.: No output offset (D2 = 0)
Channel 1
No short to V
D1
Short to V
Channel 1
D0
No short to GND (D1 = 0)
Short to GND (D1 = 1)
DB2
Offset detection not activated (D7 = 0)
D7
Offset detection activated (D7 = 1)
D6
X
D5
X
Channel 2
D4
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
Channel 2
D3
Normal load (D3 = 0)
Short load (D3 = 1)
Channel 2
Turn-on diag.: No open load (D2 = 0)
D2
Permanent diag.: No output offset (D2 = 0)
Channel 2
No short to V
D1
Short to V
Channel 2
D0
No short to GND (D1 = 0)
Short to GND (D1 = 1)
10/17
Copyright STMicroelectronics
ACTIVE
Open load detection (D2 = 1)
Output offset detection (D2 = 1)
(D1 = 0)
cc
(D1 = 1)
cc
Open load detection (D2 = 1)
Output offset detection (D2 = 1)
(D1 = 0)
cc
(D1 = 1)
cc
COMPANY INTERNAL
DATE 22-Mar-2004
page: 10/17