IC AMP AUDIO 150W AB 27FLEXIWATT

TDA7575

Manufacturer Part NumberTDA7575
DescriptionIC AMP AUDIO 150W AB 27FLEXIWATT
ManufacturerSTMicroelectronics
TypeClass AB
TDA7575 datasheets
 


Specifications of TDA7575

Output Type1-Channel (Mono) or 2-Channel (Stereo)Max Output Power X Channels @ Load150W x 1 @ 1 Ohm; 75W x 2 @ 2 Ohm
Voltage - Supply8 V ~ 18 VFeaturesDifferential Inputs, I²C, Mute, Short-Circuit and Thermal Protection, Standby
Mounting TypeThrough HolePackage / Case27-Flexiwatt (bent and staggered leads)
Operational ClassClass-ABOutput Power (typ)150x1@1Ohm/75x2@2OhmW
Audio Amplifier FunctionSpeakerTotal Harmonic Distortion0.02@1Ohm@30W%
Single Supply Voltage (typ)9/12/15VDual Supply Voltage (typ)Not RequiredV
Power Supply RequirementSinglePower Dissipation86W
Rail/rail I/o TypeNoSingle Supply Voltage (min)8V
Single Supply Voltage (max)18VDual Supply Voltage (min)Not RequiredV
Dual Supply Voltage (max)Not RequiredVOperating Temp Range-55C to 150C
Operating Temperature ClassificationMilitaryMountingSurface Mount
Pin Count36Package TypePSOP
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
Page 15/21

Download datasheet (585Kb)Embed
PrevNext
DOCUMENT CD00003142
REVISION 3.0
Examples of bytes sequence
1 - Turn-On diagnostic - Write operation
Start
Address byte with D0 = 0
2 - Turn-On diagnostic - Read operation
Start
Address byte with D0 = 1
The delay from 1 to 2 can be selected by software, starting from T.B.D. ms
3a - Turn-On of the power amplifier with mute on, diagnostic defeat.
Start
Address byte with D0 = 0
3b - Turn-Off of the power amplifier
Start
Address byte with D0 = 0
4 - Offset detection procedure enable
Start
Address byte with D0 = 0
5 - Offset detection procedure stop and reading operation (the results are valid only for the offset detection bits
(D2 of the bytes DB1, DB2, DB3, DB4).
Start
Address byte with D0 = 1
The purpose of this test is to check if a D.C. offset (2V typ.) is present on the outputs, produced by input
capacitor with anomalous leackage current or humidity between pins.
The delay from 4 to 5 can be selected by software, starting from T.B.D. ms
DIAGNOSTICS FUNCTIONAL DESCRIPTION:
a) TURN-ON DIAGNOSTIC.
It is activated at the turn-on (stand-by out) under I
– SHORT TO GND
– SHORT TO Vs
– SHORT ACROSS THE SPEAKER
– OPEN SPEAKER
To verify if any of the above misconnections are in place, a subsonic (inaudible) current pulse (fig. A) is internally
generated, sent through the speaker(s) and sunk back.The Turn On diagnostic status is internally stored until a
successive diagnostic pulse is requested (after a I2C reading).
If the "stand-by out" and "diag. enable" commands are both given through a single programming step, the pulse
takes place first (power stage still in stand-by mode, low, outputs= high impedance).
Copyright STMicroelectronics
ACTIVE
ACK
IB1 with D6 = 1
ACK
ACK
DB1
ACK
ACK
IB1
ACK
X000XXXX
XXX1XX1X
ACK
IB1
ACK
X0XXXXXX
XXX0XXXX
ACK
IB1
ACK
XX1XX1XX
XXX1XXXX
ACK
DB1
ACK
2
C bus request. Detectable output faults are:
COMPANY INTERNAL
Unauthorized reproduction and communication strictly prohibited
DATE 22-Mar-2004
page: 11/17
TDA7575PD
IB2
ACK
STOP
DB2
ACK
STOP
IB2
ACK
STOP
IB2
ACK
STOP
IB2
ACK
STOP
DB2
ACK
STOP
11/17