LM3S102 Luminary Micro, Inc, LM3S102 Datasheet - Page 52

no-image

LM3S102

Manufacturer Part Number
LM3S102
Description
Lm3s102 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S102-EQN20-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S102-EQN20-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S102-IGZ-C2
Manufacturer:
TI
Quantity:
965
Company:
Part Number:
LM3S102-IGZ-C2
Quantity:
982
Part Number:
LM3S102-IQN20-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S102-IQN20-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
System Control
Figure 6-2. Main Clock Tree
6.1.4.2
6.1.4.3
6.1.4.4
52
OSC1
OSC2
a. These are bit fields within the Run-Mode Clock Configuration (RCC) register.
PLL Frequency Configuration
The user does not have direct control over the PLL frequency, but is required to match the external
crystal used to an internal PLL-Crystal table. This table is used to create the best fit for PLL
parameters to the crystal chosen. Not all crystals result in the PLL operating at exactly 200 MHz,
though the frequency is within
Translation (PLLCTL) register (see page 79).
Table 6-4 on page 77 describes the available crystal choices and default programming of the
PLLCTL register. The crystal number is written into the XTAL field of the Run-Mode Clock
Configuration (RCC) register (see page 75). Any time the XTAL field changes, a read of the
internal table is performed to get the correct value. Table 6-4 on page 77 describes the available
crystal choices and default programming values.
PLL Modes
The PLL has two modes of operation: Normal and Power-Down
The modes are programmed using the RCC register fields as shown in Table 6-4 on page 77.
PLL Operation
If the PLL configuration is changed, the PLL output is not stable for a period of time (PLL
T
The PLL is changed by one of the following:
A counter is defined to measure the T
oscillator. The range of the internal oscillator has been taken into account and the down counter is
set to 0x3000 (that is, ~800
the PLL from being used as a system clock until the T
1-8 MHz
Internal
15 MHz
READY
Main
Osc
Osc
Normal: The PLL multiplies the input clock reference and drives the output.
Power-Down: Most of the PLL internal circuitry is disabled and the PLL does not drive the
output.
Change to the XTAL value in the RCC register (see page 75)—writes of the same value do not
cause a relock.
Change in the PLL from Power-Down to Normal mode.
=0.5 ms) and during this time, the PLL is not usable as a clock reference.
÷4
OSCSRC
μs
a
at a 15-MHz internal oscillator clock). Hardware is provided to keep
±
1%. The result of the lookup is kept in the XTAL to PLL
PWRDN
Preliminary
(200 MHz
XTAL
OEN
output )
PLL
READY
a
a
a
requirement. The counter is clocked by the internal
BYPASS
a
READY
condition is met after one of the two
SYSDIV
a
USESYSDIV
a
July 6, 2006
System Clock

Related parts for LM3S102