adt7476a Analog Devices, Inc., adt7476a Datasheet - Page 65
adt7476a
Manufacturer Part Number
adt7476a
Description
Dbcool Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADT7476A.pdf
(72 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adt7476aRQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adt7476aRQZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
Table 46. Register 0x73—Configuration Register 2 (Power-On Default = 0x00)
Bit
0
1
2
3
4
5
6
7
1
Table 47. Register 0x74—Interrupt Mask Register 1 (Power-On Default [7:0] = 0x00)
Bit
0
1
2
3
4
5
6
7
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any further attempts to write to this register have no effect.
Name
2.5V/THERM
V
V
5 V
R1T
LT
R2T
OOL
CCP
CC
Name
FanPresenceDT
Fan1Detect
Fan2Detect
Fan3Detect
AVG
ATTN
CONV
RES
R/W
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
R/W
Read/Write
Read
Read
Read
Read/Write
Read/Write
Read/Write
1
Description
2.5V/ THERM = 1, masks SMBALERT for out-of-limit conditions on the 2.5 V/ THERM timer channel.
V
V
5 V = 1 masks SMBALERT for out-of-limit conditions on the 5 V channel.
R1T = 1 masks SMBALERT for out-of-limit conditions on the Remote 1 temperature channel.
LT = 1 masks SMBALERT for out-of-limit conditions on the local temperature channel.
R2T = 1 masks SMBALERT for out-of-limit conditions on the Remote 2 temperature channel.
OOL = 0 when one or more alerts are generated in Interrupt Status Register 2, assuming all the
mask bits in the Interrupt Mask Register 2 (0x75) =1, SMBALERT is still asserted.
OOL = 1 when one or more alerts are generated in Interrupt Status Register 2, assuming all the
mask bits in the Interrupt Mask Register 2 (0x75) =1, SMBALERT is not asserted.
CCP
CC
= 1 masks SMBALERT for out-of-limit conditions on the V
= 1 masks SMBALERT for out-of-limit conditions on the V
Description
When FanPresenceDT = 1, the state of Bits [3:1] of 0x73 reflects the presence of a
4-wire fan on the appropriate TACH channel.
Fan1Detect = 1 indicates that a 4-wire fan is connected to the TACH 1 input.
Fan2Detect = 1 indicates that a 4-wire fan is connected to the TACH 2 input.
Fan3Detect = 1 indicates that a 4-wire fan is connected to the TACH 3 input.
AVG = 1 indicates that averaging on the temperature and voltage measurements is
turned off. This allows measurements on each channel to be made much faster. (x16).
ATTN = 1 indicates that the ADT7476A removes the attenuators from the +2.5V
V
connecting up external sensors. It is also possible to remove attenuators from
individual channels using Bits [7:4] of Configuration Register 4 (0x7D).
CONV = 1 indicates that the ADT7476A is put into a single-channel ADC conversion
mode. In this mode, the ADT7476A can be made to read continuously from one
input only, for example, Remote 1 temperature. The appropriate ADC channel is
selected by writing to Bits [7:5] of TACH1 minimum high byte register (0x55).
Bits [7:5] Register 0x55
000
001
010
011
100
101
110
111
This bit is reserved and should not be changed.
CCP
Rev. 0 | Page 65 of 72
, +5V
IN
, and +12V
2.5 V
V
V
5 V
12 V
Remote 1 temperature
Local temperature
Remote 2 temperature
CCP
CC
(3.3 V)
IN
inputs. These inputs can be used for other functions such as
1
CC
CCP
channel.
channel.
ADT7476A
IN
,