lm5066pmhx National Semiconductor Corporation, lm5066pmhx Datasheet - Page 31

no-image

lm5066pmhx

Manufacturer Part Number
lm5066pmhx
Description
High Voltage System Power Management And Protection Ic With Pmbus
Manufacturer
National Semiconductor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
lm5066pmhx/NOPB
Manufacturer:
NS/TI
Quantity:
24
STATUS_VOUT (7Ah)
The STATUS_VOUT command is a standard PMBus com-
mand that returns the value of the VOUT UV Warn flag.
STATUS_INPUT (7Ch)
The STATUS_INPUT command is a standard PMBus com-
mand that returns the value of a number of flags related to
input voltage, current, and power. Accesses to this command
should use the PMBus read byte protocol. To clear bits in this
STATUS_TEMPERATURE (7dh)
The STATUS_TEMPERATURE is a standard PMBus com-
mand that returns the value of the of a number of flags related
to the temperature telemetry value. Accesses to this com-
Bit
Bit
Bit
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
2
1
0
VOUT Tracking Error
Insufficient Voltage
None of the Above
TEMPERATURE
Undertemp Warn
Undertemp Fault
TOFF Max Fault
VOUT OV Warn
VOUT UV Warn
Overtemp Warn
VOUT OV Fault
VOUT UV Fault
Overtemp Fault
TON Max Fault
VIN OV Warn
VIN UV Warn
PIN OP Warn
VIN OV Fault
VIN UV Fault
IIN OC Warn
IIN OC Fault
VOUT Max
reserved
reserved
reserved
reserved
NAME
NAME
NAME
NAME
CML
TABLE 13. STATUS_TEMPERATURE Definitions
TABLE 12. STATUS_INPUT Definitions
TABLE 11. STATUS_VOUT Definitions
A fault or warning not listed in bits [7:1] has occurred
A Temperature Fault or Warning has occurred
A VOUT Under-voltage Warning has occurred
An Overtemperature Warning has occurred
A VIN Under-voltage Warning has occurred
A VIN Over-voltage Warning has occurred
An IIN Over-current Warning has occurred
A PIN Over-power Warning has occurred
An Overtemperature Fault has occurred
A VIN Under-voltage Fault has occurred
An IIN Over-current Fault has occurred
31
A VIN Over-voltage Fault has occurred
A Communication Fault has occurred
Accesses to this command should use the PMBus read byte
protocol. To clear bits in this register, the underlying fault
should be cleared and a CLEAR_FAULTS command issued.
register, the underlying fault should be cleared and a
CLEAR_FAULTS command issued. The VIN UV Warn flag
will default to 1 on startup, however, it will be cleared to 0 after
the first time the input voltage increases above the resistor-
programmed UVLO threshold.
mand should use the PMBus read byte protocol. To clear bits
in this register, the underlying fault should be cleared and a
CLEAR_FAULTS command issued.
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Not Supported, always 0
Meaning
Meaning
Meaning
Meaning
Default
Default
Default
Default
www.national.com
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0

Related parts for lm5066pmhx