xr16m890 Exar Corporation, xr16m890 Datasheet - Page 45

no-image

xr16m890

Manufacturer Part Number
xr16m890
Description
Uart With 128-byte Fifo And Integrated Level Shifters
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16m890IL32-F
Manufacturer:
EXAR
Quantity:
1 420
Part Number:
xr16m890IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16m890IL40-F
Quantity:
700
Company:
Part Number:
xr16m890IL40-F
Quantity:
3 300
Part Number:
xr16m890IM48-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr16m890IM48-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16m890IM48-F
Quantity:
412
Part Number:
xr16m890IM48TR-F
Manufacturer:
Exar Corporation
Quantity:
10 000
REV. P1.1.1
EMSR[7]: Xoff/Special character Interrupt Mode Select
This bit selects how the Xoff and Special character interrupt is cleared. The XON interrupt can only be cleared
by reading the ISR register.
These registers make-up the value of the baud rate divisor. The M890 has different DLL, DLM and DLD for
transmitter and receiver. It provides more convenience for the transmitter and receiver to transmit data with
different rate. The M890 uses DLD[7:6] to select TX or RX. Then it provides DLD[5:0] to select the sampling
frequency and fractional baud rate divisor. The concatenation of the contents of DLM and DLL gives the 16-bit
divisor value. The value is added to DLD[3:0]/16 to achieve the fractional baud rate divisor. DLD must be
enabled via EFR bit-4 before it can be accessed. See
Baud Rate Generator with Fractional Divisor” on page 15.
DLD[5:4]: Sampling Rate Select
These bits select the data sampling rate. By default, the data sampling rate is 16X. The maximum data rate will
double if the 8X mode is selected and will quadruple if the 4X mode is selected. See
DLD[6]: Independent BRG enable
DLD[7]: BRG select
When DLD[6] = 1, this bit selects whether the values written to DLL, DLM and DLD[5:0] will be for the Transmit
Baud Rate Generator or the Receive Baud Rate Generator. When DLD[6] = 0 (same Baud Rate Generator
used for both TX and RX), this bit must be a logic 0 to properly write to the appropriate DLL, DLM and
DLD[5:0].
3.15
Logic 0 = Xoff interrupt is cleared by either reading ISR register or when an XON character is received.
Special character interrupt is cleared by either reading ISR register or when next character is received.
(default).
Logic 1 = Xoff/Special character interrupt can only be cleared by reading the ISR register.
Logic 0 = The Transmitter and Receiver uses the same Baud Rate Generator. (default).
Logic 1 = The Transmitter and Receiver uses different Baud Rate Generators. Use DLD[7] for selecting
which baud rate generator to configure.
Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write
DLD[5]
0
0
1
T
UART WITH 128-BYTE FIFO AND INTEGRATED LEVEL SHIFTERS
ABLE
15: S
PRELIMINARY
AMPLING
DLD[4]
45
X
Table 15
0
1
R
ATE
below and
S
ELECT
See ”Section 1.8, Programmable
Table 15
S
AMPLING
16X
8X
4X
R
below.
XR16M890
ATE

Related parts for xr16m890