MAX11329ATJ+ Maxim Integrated, MAX11329ATJ+ Datasheet - Page 30

no-image

MAX11329ATJ+

Manufacturer Part Number
MAX11329ATJ+
Description
Analog to Digital Converters - ADC 10Bit 16Ch 3Mbps Precision ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX11329ATJ+

Rohs
yes
Number Of Channels
16/8
Architecture
SAR
Conversion Rate
3 MSPs
Resolution
10 bit
Input Type
Single-Ended/Pseudo-Differential
Snr
72.3 dB
Interface Type
BiCMOS
Operating Supply Voltage
1.5 V to 3.6 V, 2.35 V to 3.6 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
TQFN-EP-32
Maximum Power Dissipation
2758 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
External
Table 12. Custom Scan0 Register
Table 13. Custom Scan1 Register
Table 14. SampleSet Register
Maxim Integrated
CUST_SCAN1
SEQ_LENGTH
CUST_SCAN0
CHSCAN15
CHSCAN14
CHSCAN13
CHSCAN12
CHSCAN11
CHSCAN10
BIT NAME
BIT NAME
SMPL_SET
BIT NAME
CHSCAN7
CHSCAN6
CHSCAN5
CHSCAN4
CHSCAN3
CHSCAN2
CHSCAN1
CHSCAN0
CHSCAN9
CHSCAN8
Post-Mux External Signal Conditioning Access
3Msps, 12-/10-Bit, 8-/16-Channel ADCs with
15:11
15:11
10:3
BIT
2:0
BIT
2:0
10
9
8
7
6
5
4
3
15:11
BIT
2:0
10
9
8
7
6
5
4
3
DEFAULT
DEFAULT STATE
STATE
000
00000000
0
0
0
0
0
0
0
0
DEFAULT
STATE
000
0
0
0
0
0
0
0
0
Set to 10100 to select the Custom Scan0 register.
Set to 1 to scan AIN15. Set to 0 to omit AIN15.
Set to 1 to scan AIN14. Set to 0 to omit AIN14.
Set to 1 to scan AIN13. Set to 0 to omit AIN13.
Set to 1 to scan AIN12. Set to 0 to omit AIN12.
Set to 1 to scan AIN11. Set to 0 to omit AIN11.
Set to 1 to scan AIN10. Set to 0 to omit AIN10.
Set to 1 to scan AIN9. Set to 0 to omit AIN9.
Set to 1 to scan AIN8. Set to 0 to omit AIN8.
Unused.
Set to 10110 to select the SampleSet register.
8-bit binary word indicating desired sequence length. The equation is:
Sequence length = SEQ_LENGTH + 1
00000000 = Sequence length = 1
11111111 = Sequence length = 256
Coding: Straight binary
Maximum length: 256 ADC conversions
Unused.
Set to 10101 to select the Custom Scan1 register.
Set to 1 to scan AIN7. Set to 0 to omit AIN7.
Set to 1 to scan AIN6. Set to 0 to omit AIN6.
Set to 1 to scan AIN5. Set to 0 to omit AIN5.
Set to 1 to scan AIN4. Set to 0 to omit AIN4.
Set to 1 to scan AIN3. Set to 0 to omit AIN3.
Set to 1 to scan AIN2. Set to 0 to omit AIN2.
Set to 1 to scan AIN1. Set to 0 to omit AIN1.
Set to 1 to scan AIN0. Set to 0 to omit AIN0.
Unused.
MAX11329–MAX11332
FUNCTION
FUNCTION
FUNCTION
30

Related parts for MAX11329ATJ+