M24LR64E-RDW6T/2 STMicroelectronics, M24LR64E-RDW6T/2 Datasheet - Page 30

no-image

M24LR64E-RDW6T/2

Manufacturer Part Number
M24LR64E-RDW6T/2
Description
EEPROM 64Kbit EEProm 400kHz 13.56Mhz 1.8 to 5.5V
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24LR64E-RDW6T/2

Rohs
yes
Memory Size
64 Kbit
Organization
8192 x 8
Data Retention
40 yr
Maximum Clock Frequency
400 kHz
Maximum Operating Current
20 uA
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Operating Temperature
+ 90 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-8
Access Time
900 ns
Interface Type
I2C
Minimum Operating Temperature
0 C
Operating Current
20 uA
Supply Voltage - Max
5.5 V
Supply Voltage - Min
1.8 V
System memory area
4.3.3
Note:
4.3.4
4.3.5
4.4
30/140
FIELD_ON indicator bit
The FIELD_ON indicator bit located as bit 1 of the Control register is a read-only bit used to
indicate when the RF power level delivered to the M24LR64E-R is sufficient to execute RF
commands.
During read access to the Control register in RF mode, the FIELD_ON bit is always read
at 1.
Configuration byte access in I²C and RF modes
In I²C mode, read and write accesses to the non-volatile Configuration byte are always
allowed. To access the Configuration byte, the device select code used for any I²C
command must have the E2 Chip enable address at 1.
The dedicated commands to access the Configuration byte in RF mode are:
After any write access to the Configuration byte, the new configuration is automatically
applied.
Control register access in I²C or RF mode
In I²C mode, read and write accesses to the volatile Control register are always allowed. To
access the Control register, the device select code used for any I²C command must have the
E2 Chip enable address at 1.
The dedicated commands to access the Control register in RF mode are:
ISO 15693 system parameters
The M24LR64E-R provides the system area required by the ISO 15693 RF protocol, as
shown in
The first 32-bit block starting from I
is used to activate/deactivate the write protection of the protected sector in I
When FIELD_ON = 0, the M24LR64E-R is not able to execute any RF commands.
When FIELD_ON =1, the M24LR64E-R is able to execute any RF commands.
Read configuration byte command (ReadCfg):
Write energy harvesting configuration command (WriteEHCfg):
Write RF WIP/BUSY pin configuration command (WriteDOCfg):
Check energy harvesting enable bit command (CheckEHEn):
Set/reset energy harvesting enable bit command (SetRstEHEn):
Table
The ReadCfg command is used to read the eight bits of the Configuration byte.
The WriteEHCfg command is used to write the EH_mode, EH_cfg1 and EH_cfg0
bits into the Configuration byte.
The WriteDOCfg command is used to write the RF WIP/BUSY bit into the
Configuration byte.
The CheckEHEn command is used to read the eight bits of the Control register.
When it is run, the FIELD_ON bit is always read at 1.
The SetRstEHEn command is used to set or reset the value of the EH_enable bit
into the Control register.
17.
Doc ID 022712 Rev 3
2
C address 2304 stores the I
2
C password. This password
2
C mode. At
M24LR64E-R

Related parts for M24LR64E-RDW6T/2