Specifications of M29W160EB70N6F

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
16M (2M x 8 or 1M x 16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Package
48TSOP
Cell Type
NOR
Density
16 Mb
Architecture
Sectored
Block Organization
Asymmetrical
Location Of Boot Block
Bottom
Typical Operating Supply Voltage
3|3.3 V
Sector Size
8KByte x 2|16KByte x 1|32KByte x 1|64KByte x 31
Timing Type
Asynchronous
Interface Type
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W160EB70N6F
Manufacturer:
MIDCOM
Quantity:
433
Part Number:
M29W160EB70N6F
Manufacturer:
ST
0
Part Number:
M29W160EB70N6F
Manufacturer:
MICRON/美光
Quantity:
20 000
Company:
Part Number:
M29W160EB70N6F
Quantity:
4 425
Company:
Part Number:
M29W160EB70N6F
Quantity:
500
Table 3. Bus Operations, BYTE = V
Note: X = V
COMMAND INTERFACE
All Bus Write operations to the memory are inter-
preted by the Command Interface. Commands
consist of one or more sequential Bus Write oper-
ations. Failure to observe a valid sequence of Bus
Write operations will result in the memory return-
ing to Read mode. The long command sequences
are imposed to maximize data security.
The address used for the commands changes de-
pending on whether the memory is in 16-bit or 8-
bit mode. See either Table 4, or 5, depending on
the configuration that is being used, for a summary
of the commands.
Read/Reset Command. The Read/Reset com-
mand returns the memory to its Read mode where
it behaves like a ROM or EPROM, unless other-
wise stated. It also resets the errors in the Status
Register. Either one or three Bus Write operations
can be used to issue the Read/Reset command.
The Read/Reset Command can be issued, be-
tween Bus Write cycles before the start of a pro-
gram or erase operation, to return the device to
read mode. Once the program or erase operation
has started the Read/Reset command is no longer
accepted. The Read/Reset command will not
abort an Erase operation when issued while in
Erase Suspend.
Auto Select Command. The Auto Select com-
mand is used to read the Manufacturer Code, the
Device Code and the Block Protection Status.
Three consecutive Bus Write operations are re-
quired to issue the Auto Select command. Once
the Auto Select command is issued the memory
remains in Auto Select mode until a Read/Reset
command is issued. Read CFI Query and Read/
Reset commands are accepted in Auto Select
mode, all other commands are ignored.
Bus Read
Bus Write
Output Disable
Standby
Read Manufacturer
Code
Read Device Code
Operation
IL
or V
IH
.
V
V
V
V
V
E
X
IH
IL
IL
IL
IL
V
V
V
V
V
G
X
IH
IH
IL
IL
IL
IH
V
V
V
V
V
W
X
IH
IH
IH
IH
IL
Cell Address
Command Address
X
X
A0 = V
Others V
A0 = V
Others V
Address Inputs
IH
IL
, A1 = V
, A1 = V
IL
IL
From the Auto Select mode the Manufacturer
Code can be read using a Bus Read operation
with A0 = V
may be set to either V
Code for Numonyx is 0020h.
The Device Code can be read using a Bus Read
operation with A0 = V
address bits may be set to either V
Device Code for the M29W160ET is 22C4h and
for the M29W160EB is 2249h.
The Block Protection Status of each block can be
read using a Bus Read operation with A0 = V
A1 = V
the block. The other address bits may be set to ei-
ther V
then 01h is output on Data Inputs/Outputs DQ0-
DQ7, otherwise 00h is output.
Program Command. The Program command
can be used to program a value to one address in
the memory array at a time. The command re-
quires four Bus Write operations, the final write op-
eration latches the address and data, and starts
the Program/Erase Controller.
If the address falls in a protected block then the
Program command is ignored, the data remains
unchanged. The Status Register is never read and
no error condition is given.
During the program operation the memory will ig-
nore all commands. It is not possible to issue any
command to abort or pause the operation. Typical
program times are given in Table 6. Bus Read op-
erations during the program operation will output
the Status Register on the Data Inputs/Outputs.
See the section on the Status Register for more
details.
After the program operation has completed the
memory returns to the Read mode, unless an error
A0-A19
or V
or V
IH
IH
IL
IL
IL
IH
, A9 = V
, A9 = V
or V
, and A12-A19 specifying the address of
IL
IH
and A1 = V
. If the addressed block is protected
ID
ID
,
,
M29W160ET, M29W160EB
IL
IH
DQ15A–1, DQ14-DQ0
22C4h (M29W160ET)
2249h (M29W160EB)
Data Inputs/Outputs
or V
IL
and A1 = V
. The other address bits
Data Output
IH
Data Input
. The Manufacturer
0020h
Hi-Z
Hi-Z
IL
IL
or V
. The other
IH
. The
13/42