SA56004EDP,118 NXP Semiconductors, SA56004EDP,118 Datasheet - Page 17

IC TEMP SENSOR 8-TSSOP

SA56004EDP,118

Manufacturer Part Number
SA56004EDP,118
Description
IC TEMP SENSOR 8-TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004EDP,118

Package / Case
8-TSSOP
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
1 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-3615 - DEMO BOARD I2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-3338-2
935274567118
SA56004EDP-T
NXP Semiconductors
SA56004X_5
Product data sheet
7.9.4 Remote diode selection
7.9.5 Diode fault detection
To measure the remote temperature or the temperature of an externally attached diode,
the device automatically forces two successive currents of about 160 A and 10 A at D+
pin. It measures the voltage (V
two V
the basic PTAT voltage formula as shown in
38 ms to perform a measurement during each conversion period or cycle, which is
selectable by programming the conversion rate register.
Where:
Because the device does not directly convert the sensed V
temperature measurement systems, the V
device remote temperature error is adjusted at the manufacturer to meet the specifications
with the use of the reference diode-connected transistors such as the 2N3904/2N3906.
The diode type to be used in customer applications must have the characteristics as close
to the 2N3904/2N3906 as possible in order to obtain optimal results. Finally, to prevent the
effects of system noise on the measured V
2200 pF connected between the D+ and D pins as well as the grounded-shield cable for
the diode connection wires are recommended.
The SA56004X is designed with circuitry to detect the fault conditions of the remote diode.
When the D+ pin is shorted to V
register is loaded with +127 C, the Remote Temperature Low Byte (RTLB) register is
loaded with 0 C, and the OPEN bit (bit 2 of the Status register) is set. Under the above
conditions of D+ shorted to V
+127 C, and T_CRIT Mask are disabled, then, the T_CRIT output pins will be pulled
V
Event F: Three consecutive measurements have been made with the remote
temperature below the RCS
HIGH).
Event G: The remote temp falls below the Remote LOW setpoint.
Event H: Three consecutive measurements are made with the temp below the Remote
LOW setpoint; ALERT output is activated (goes LOW).
Event I: The ALERT output is de-activated (goes HIGH) after a above_low_limit
temperature measurement is completed.
n = diode ideality factor
k = Boltzmann’s constant
T = absolute temperature ( K) = 273 C + T ( C)
q = electron charge
ln = natural logarithm
l2, l1 = two source currents
BE
BE
=
voltages or the V
n
kT
------
q
ln
l2
---- -
l1
Rev. 05 — 22 May 2008
BE
DD
Digital temperature sensor with overtemperature alarms
and then converts the V
BE
DD
or floating, if the Remote T_CRIT setpoint is set less than
TH threshold; the T_CRIT output is de-activated (goes
) between D+ and D , detects the difference between the
or floating, the Remote Temperature High Byte (RTHB)
BE
BE
Equation
calibration is not required. Furthermore, the
signals, an external capacitor of about
1. The device typically takes about
BE
into a temperature data using
BE
as in the old method of
SA56004X
© NXP B.V. 2008. All rights reserved.
17 of 36
(1)