SA56004EDP,118 NXP Semiconductors, SA56004EDP,118 Datasheet - Page 6

IC TEMP SENSOR 8-TSSOP

SA56004EDP,118

Manufacturer Part Number
SA56004EDP,118
Description
IC TEMP SENSOR 8-TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004EDP,118

Package / Case
8-TSSOP
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
1 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
568-3615 - DEMO BOARD I2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-3338-2
935274567118
SA56004EDP-T
NXP Semiconductors
Table 4.
SA56004X_5
Product data sheet
Register
name
LTHB
RTHB
SR
CON
CR
LHS
LLS
RHSHB
RLSHB
One Shot
RTLB
RTOHB
RTOLB
RHSLB
RLSLB
RCS
LCS
TH
ATLB
AM
RMID
RDR
Register assignments
Command byte
Read
address
00h
01h
02h
03h
04h
05h
06h
07h
08h
n/a
10h
11h
12h
13h
14h
19h
20h
21h
22h
BFh
FEh
FFh
7.4 Power-on reset
When power is applied to the SA56004X, the device will enter into its Power-On Reset
(POR) state and its registers are reset to their default values. The configuration, status,
and temperature-reading registers remain in these states until after the first conversion.
As shown in
1. Command register set to 00h.
2. Local Temperature register (LTHB and LTLB) set to 0 C.
3. Remote Diode Temperature register (RTHB and RTLB) set to 0 C until the end of the
4. Status register (SR) set to 00h.
5. Configuration register (CON) set to 00h; interrupt latches are cleared, the ALERT and
6. Local T_CRIT temperature setpoints (LCS) and Remote T_CRIT temperature
7. Local HIGH setpoint (LHS) and remote HIGH temperature setpoint (RHSHB) at 70 C.
Write
address
n/a
n/a
n/a
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
n/a
11h
12h
13h
14h
19h
20h
21h
n/a
BFh
n/a
n/a
first conversion.
T_CRIT output drivers are off and the ALERT and T_CRIT pins are pulled HIGH by
the external pull-up resistors.
setpoints (RCS) at 85 C.
Table 4
POR state
0000 0000
0000 0000
0000 0000
0000 0000
1000
0100 0110
0000 0000
0100 0110
0000 0000
-
0000 00
0000 0000
000
000
000
0101 0101
0101 0101
0 1010
0000 0000
0
1010 0001
0000 0000
this results in:
Rev. 05 — 22 May 2008
Function
local temperature high byte
remote temperature high byte
status register
configuration register
conversion rate
local high setpoint
local low setpoint
remote high setpoint high byte
remote low setpoint high byte
writing register initiates a one shot conversion 0
remote temperature low byte
remote temperature offset high byte
remote temperature offset low byte
remote high setpoint low byte
remote low setpoint low byte
remote T_CRIT setpoint
local T_CRIT setpoint
T_CRIT hysteresis
local temperature low byte
Alert mode
read manufacturer’s ID
read stepping or die revision
Digital temperature sensor with overtemperature alarms
SA56004X
Bits
8
8
8
8
4
8
8
8
8
6 (MSBs)
8
3 (MSBs)
3 (MSBs)
3 (MSBs)
8
8
5
3 (MSBs)
1
8
8
© NXP B.V. 2008. All rights reserved.
Access
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
W
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R/W
R
R
6 of 36

Related parts for SA56004EDP,118