SAF-XE167F-96F66L AC Infineon Technologies, SAF-XE167F-96F66L AC Datasheet - Page 98

IC MCU 16BIT FLASH PG-LQFP-144

SAF-XE167F-96F66L AC

Manufacturer Part Number
SAF-XE167F-96F66L AC
Description
IC MCU 16BIT FLASH PG-LQFP-144
Manufacturer
Infineon Technologies
Series
XE16xr
Datasheet

Specifications of SAF-XE167F-96F66L AC

Core Processor
C166SV2
Core Size
16-Bit
Speed
66MHz
Connectivity
CAN, EBI/EMI, I²C, LIN, SPI, SSC, UART/USART, USI
Peripherals
I²S, POR, PWM, WDT
Number Of I /o
118
Program Memory Size
768KB (768K x 8)
Program Memory Type
FLASH
Ram Size
82K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 24x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LFQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
FXE167F96F66LACXP
SAF-XE167F-96F66LACIN
SP000363803
The timing in the AC Characteristics refers to TCSs. Timing must be calculated using the
minimum TCS possible under the given circumstances.
The actual minimum value for TCS depends on the jitter of the PLL. Because the PLL is
constantly adjusting its output frequency to correspond to the input frequency (from
crystal or oscillator), the accumulated jitter is limited. This means that the relative
deviation for periods of more than one TCS is lower than for a single TCS (see formulas
and
This is especially important for bus cycles using waitstates and for the operation of
timers, serial interfaces, etc. For all slower operations and longer periods (e.g. pulse train
generation or measurement, lower baudrates, etc.) the deviation caused by the PLL jitter
is negligible.
The value of the accumulated PLL jitter depends on the number of consecutive VCO
output cycles within the respective timeframe. The VCO output clock is divided by the
output prescaler K2 to generate the system clock signal
is K2 × T, where T is the number of consecutive
The maximum accumulated jitter (long-term jitter) D
D
This maximum value is applicable, if either the number of clock cycles T > (
the prescaler value K2 > 17.
In all other cases for a timeframe of T × TCS the accumulated jitter D
D
f
Example, for a period of 3 TCSs @ 33 MHz and K2 = 4:
D
D
= 5.97 × [0.768 × 2 / 26.39 + 0.232]
= 1.7 ns
Example, for a period of 3 TCSs @ 33 MHz and K2 = 2:
D
D
= 7.63 × [0.884 × 2 / 26.39 + 0.116]
= 1.4 ns
Data Sheet
SYS
Tmax
T
max
3
max
3
= 5.97 × [(1 - 0.058 × 4) × (3 - 1) / (0.83 × 33 - 1) + 0.058 × 4]
= 7.63 × [(1 - 0.058 × 2) × (3 - 1) / (0.83 × 33 - 1) + 0.058 × 2]
[ns] = D
Figure
in [MHz] in all formulas.
= ±(220 / (4 × 33) + 4.3) = 5.97 ns (Not applicable directly in this case!)
= ±(220 / (2 × 33) + 4.3) = 7.63 ns (Not applicable directly in this case!)
[ns] = ±(220 / (K2 ×
Tmax
19).
× [(1 - 0.058 × K2) × (T - 1) / (0.83 ×
f
SYS
) + 4.3)
96
f
SYS
Tmax
f
cycles (TCS).
SYS
f
SYS
is defined by:
XE166 Family Derivatives
- 1) + 0.058 × K2]
. The number of VCO cycles
Electrical Parameters
T
is determined by:
V2.1, 2008-08
f
SYS
XE167x
/ 1.2) or