Z8F6422AR020SC2104 Zilog, Z8F6422AR020SC2104 Datasheet - Page 104

IC ENCORE MCU FLASH 64K 64LQFP

Z8F6422AR020SC2104

Manufacturer Part Number
Z8F6422AR020SC2104
Description
IC ENCORE MCU FLASH 64K 64LQFP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F6422AR020SC2104

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
46
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
64-LQFP
For Use With
269-4678 - KIT DEV FOR Z8F642 MCU 44 PIN269-4677 - KIT DEV FOR Z8F642 MCU 28PIN269-4540 - KIT DEV FOR Z8 ENCORE 16K TO 64K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
269-3641

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F6422AR020SC2104
Manufacturer:
Zilog
Quantity:
10 000
Table 46. Timer 0-3 Control 1 Register (TxCTL1)
PS019921-0308
BITS
FIELD
RESET
R/W
ADDR
Timer 0-3 Control 1 Registers
TEN
7
The Timer 0-3 Control 1 (TxCTL1) registers enable/disable the timers, set the prescaler
value, and determine the timer operating mode.
TEN—Timer Enable
0 = Timer is disabled.
1 = Timer enabled to count.
TPOL—Timer Input/Output Polarity
Operation of this bit is a function of the current operating mode of the timer.
ONE-SHOT mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
CONTINUOUS mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
COUNTER mode
When the timer is disabled, the Timer Output signal is set to the value of this bit.
When the timer is enabled, the Timer Output signal is complemented upon timer
Reload.
0 = Count occurs on the rising edge of the Timer Input signal.
1 = Count occurs on the falling edge of the Timer Input signal.
PWM mode
0 = Timer Output is forced Low (0) when the timer is disabled. When enabled,
the Timer Output is forced High (1) upon PWM count match and forced
Low (0) upon Reload.
TPOL
6
5
F07H, F0FH, F17H, F1FH
PRES
4
R/W
0
3
Z8 Encore! XP
2
Product Specification
TMODE
1
®
F64XX Series
0
Timers
90