XK-Z11-M Digi International, XK-Z11-M Datasheet - Page 110

no-image

XK-Z11-M

Manufacturer Part Number
XK-Z11-M
Description
ZIGBEE MODULE DEVELOPMENT KIT
Manufacturer
Digi International
Series
XBee™r
Type
Transceiver, 802.15.4/ZigBeer
Datasheets

Specifications of XK-Z11-M

Frequency
2.4GHz
For Use With/related Products
XBee Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1184
© 2010 Digi International, Inc.
XBee®/XBee‐PRO® ZB RF Modules 
AT Command Response
Modem Status
Frame Type: 0x88
In response to an AT Command message, the module will send an AT Command Response message. Some
commands will send back multiple frames (for example, the ND (Node Discover) command).
Frame Type: (0x8A)
RF module status messages are sent from the module in response to specific conditions.
Note: New modem status codes may be added in future firmware releases.
Example: Suppose the BD parameter is changed on the local device with a frame ID of 0x01. If
successful (parameter was valid), the above response would be received.
Example: The following API frame is returned when an API coordinator forms a network.
A
P
I
P
a
c
k
e
t
A
P
I
P
a
c
k
e
t
Start Delimiter
Length
Frame-specific Data
Checksum
Start Delimiter
Length
Frame-specific Data
Checksum
Frame Fields
Frame Fields
Frame Type
Frame ID
AT Command
Command Status
Command Data
Frame Type
Status
Offset Example
Offset Example
MSB 1 0x00
MSB 1 0x00
LSB 2 0x05
LSB 2 0x02
0 0x7E
3 0x88
4 0x01
5 ‘B’ = 0x42
6 ‘D’ = 0x44
7 0x00
8 0xF0
0 0x7E
3 0x8A
4 0x06
5 0x6F
Number of bytes between the length and the checksum
Identifies the UART data frame being reported. Note: If
Frame ID = 0 in AT Command Mode, no AT Command
Response will be given.
Command Name - Two ASCII characters that identify the
AT Command.
0 = OK
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
4 = Tx Failure
Register data in binary format. If the register was set,
then this field is not returned, as in this example.
0xFF - the 8 bit sum of bytes from offset 3 to this byte.
Number of bytes between the length and the checksum
0 = Hardware reset
1 = Watchdog timer reset
2 =Joined network (routers and end devices)
3 =Disassociated
6 =Coordinator started
7 = Network security key was updated
0x0D = Voltage supply limit exceeded (PRO S2B only)
0x11 = Modem configuration changed while join in
progress
0x80+ = stack error
0xFF - the 8 bit sum of bytes from offset 3 to this byte.
Description
Description
     109

Related parts for XK-Z11-M