XK-Z11-M Digi International, XK-Z11-M Datasheet - Page 127

no-image

XK-Z11-M

Manufacturer Part Number
XK-Z11-M
Description
ZIGBEE MODULE DEVELOPMENT KIT
Manufacturer
Digi International
Series
XBee™r
Type
Transceiver, 802.15.4/ZigBeer
Datasheets

Specifications of XK-Z11-M

Frequency
2.4GHz
For Use With/related Products
XBee Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1184
© 2010 Digi International, Inc.
XBee®/XBee‐PRO® ZB RF Modules 
A
P
I
P
a
c
k
e
t
Start Delimiter
Length
Frame-specific
Data
Frame Type
Frame ID
64-bit
Destination
Address
16-bit
Destination
Network
Address
Source
Endpoint
Destination
Endpoint
Cluster ID
Profile ID
Broadcast
Radius
Transmit
Options
Data Payload
Frame Fields
ZCL Frame
Header
Frame Control
Transaction
Sequence
Number
Offset Example
MSB 13 0x56
MSB 17 0x07
MSB 19 0x01
LSB 14 0x78
LSB 18 0x01
LSB 20 0x09
MSB 1 0x00
MSB 5 0x00
LSB 2 0x19
10 0x40
12 0x34
15 0x41
16 0x42
21 0x00
22 0x00
23 0x09
24 0x01
25 0x00
11 0x12
0 0x7E
3 0x11
4 0x01
6 0x13
7 0xA2
8 0x00
9 0x40
Number of bytes between the length and the checksum
Identifies the UART data frame for the host to correlate
with a subsequent transmit status. If set to 0, no transmit
status frame will be sent out the UART.
64-bit address of the destination device (big endian byte
order). For unicast transmissions, set to the 64-bit
address of the destination device, or to
0x0000000000000000 to send a unicast to the
coordinator. Set to 0x000000000000FFFF for broadcast.
16-bit address of the destination device (big endian byte
order). Set to 0xFFFE for broadcast, or if the 16-bit
address is unknown.
Set to the source endpoint on the sending device. (0x41
arbitrarily selected).
Set to the destination endpoint on the remote device.
(0x42 arbitrarily selected)
Set to the cluster ID that corresponds to the ZCL
command being sent.
0x0701 = Demand response and load control cluster ID
Set to the profile ID supported on the device.
0x0109 = Smart Energy profile ID.
Sets the maximum number of hops a broadcast
transmission can traverse. If set to 0, the transmission
radius will be set to the network maximum hops value.
All bits must be set to 0.
Bitfield that defines the command type and other relevant
information in the ZCL command. See the ZCL
specification for details.
A sequence number used to correlate a ZCL command
with a ZCL response. (The hardware version response
will include this byte as a sequence number in the
response.) The value 0x01 was arbitrarily selected.
Since the frame control "frame type" bits are 01, this byte
specifies a cluster-specific command. Command ID 0x00
in the Demand Response and Load Control cluster is a
Load Control Event command. (See Smart Energy
specification.)
Description
     126