Specifications of ML610Q432A-NNNTC03A7

Core Processor
nX-U8/100
Core Size
8-Bit
Speed
4.2MHz
Connectivity
I²C, SSP, UART/USART
Peripherals
LCD, Melody Driver, POR, PWM, WDT
Number Of I /o
14
Program Memory Size
64KB (32K x 16)
Program Memory Type
FLASH
Ram Size
3K x 8
Voltage - Supply (vcc/vdd)
1.1 V ~ 3.6 V
Data Converters
A/D 2x12b, 2x24b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 70°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ML610Q432A-NNNTC03A7
Manufacturer:
Rohm
Quantity:
750
Part Number:
ML610Q432A-NNNTC03A7
Manufacturer:
Rohm Semiconductor
Quantity:
10 000
4.2.2
stop code acceptor is enabled. When the STP bit of the standby control register (SBYCON) is set to “1” in this state,
Address: 0F008H
Access: W
Access size: 8 bits
Initial value: ⎯ (Undefined)
STPACP is a write-only special function register (SFR) that is used for setting a STOP mode.
When STPACP is read, “00H” is read.
When data is written to STPACP in the order of “5nH”(n: an arbitrary value) and “0AnH”(n: an arbitrary value), the
the mode is changed to the STOP mode. When the STOP mode is set, the STOP code acceptor is disabled.
When another instruction is executed between the instruction that writes “5nH” to STPACP and the instruction that
writes “0AnH”, the stop code acceptor is enabled after “0AnH” is written. However, if data other than “0AnH” is
written to STPACP after “5nH” is written, the “5nH” write processing becomes invalid so that data must be written
again starting from “5nH”.
During a system reset, the stop code acceptor is disabled.
Note:
The STOP code acceptor can not be enabled on the condition of that both any interrupt enable flag and the
corresponding interrupt request flag are “1”(An interrupt request occurrence with resetting MIE flag will have the
condition).
Initial value
STPACP
W
Stop Code Acceptor (STPACP)
W
7
W
6
W
5
W
4
4 – 3
W
3
ML610Q431/ML610Q432 User’s Manual
Chapter 4 MCU Control Function
W
2
W
1
W
0