AD5522JSVDZ Analog Devices Inc, AD5522JSVDZ Datasheet - Page 18

IC, DAC, 16BIT, QFP-80

AD5522JSVDZ

Manufacturer Part Number
AD5522JSVDZ
Description
IC, DAC, 16BIT, QFP-80
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5522JSVDZ

Resolution (bits)
16bit
Input Channel Type
Serial
Supply Voltage Range - Digital
2.3V To 5.25V
Supply Current
36mA
Digital Ic Case Style
QFP
No. Of Pins
80
Data Interface
LVDS, Serial
Design Resources
Parametric Measurement Unit and Supporting Components for PAD Appls Using AD5522 and AD7685 (CN0104)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5522JSVDZ
Manufacturer:
WD
Quantity:
1 000
Part Number:
AD5522JSVDZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD5522JSVDZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD5522
Pin No.
49
52
53
54
55
56
57
58
59
61
63
64
65
66
68
70
71
72
73
75
76
77
78
80
Mnemonic
MEASVH3
MEASVH1
GUARDIN1/
DUTGND1
GUARD1
FOH1
EXTMEASIL1
EXTMEASIH1
CCOMP1
CFF1
EXTFOH1
MEASOUT3
MEASOUT2
MEASOUT1
MEASOUT0
SYS_FORCE
SYS_SENSE
REFGND
VREF
DUTGND
SPI/LVDS
CGALM
TMPALM
RESET
EXTFOH0
Description
DUT Voltage Sense Input (High Sense) for Channel 3.
DUT Voltage Sense Input (High Sense) for Channel 1.
Guard Output Drive for Channel 1.
Sense Input (Low Sense) for High Current Range (Channel 1).
Sense Input (High Sense) for High Current Range (Channel 1).
Compensation Capacitor Input for Channel 1. See the Compensation Capacitors section.
External Force Signal Input. This pin enables the connection of the system PMU.
External Sense Signal Output. This pin enables the connection of the system PMU.
Accurate Analog Reference Input Ground.
Reference Input for DAC Channels (5 V for specified performance).
Interface Select Pin. Logic low selects SPI-compatible interface mode; logic high selects LVDS interface mode.
Guard Amplifier Input for Channel 1/DUTGND Input for Channel 1. This dual function pin is configured via the
serial interface. The default function at power-on is GUARDIN1. If this pin is configured as a DUTGND input for
the channel, the input to the guard amplifier is internally connected to MEASVH1. For more information, see
the Device Under Test Ground (DUTGND) section and the Guard Amplifier section.
Force Output for Internal Current Ranges (Channel 1).
External Capacitor for Channel 1. This pin optimizes the stability and settling time performance of the force
amplifier when in force voltage mode. See the Compensation Capacitors section.
Force Output for High Current Range (Channel 1). Use an external resistor at this pin for current ranges up to
±80 mA. For more information, see the Current Range Selection section.
Multiplexed DUT Voltage, Current Sense Output, Temperature Sensor Voltage for Channel 3. This pin is
referenced to AGND.
Multiplexed DUT Voltage, Current Sense Output, Temperature Sensor Voltage for Channel 2. This pin is
referenced to AGND.
Multiplexed DUT Voltage, Current Sense Output, Temperature Sensor Voltage for Channel 1. This pin is
referenced to AGND.
Multiplexed DUT Voltage, Current Sense Output, Temperature Sensor Voltage for Channel 0. This pin is
referenced to AGND.
DUT Voltage Sense Input (Low Sense). By default, this input is shared among all four PMU channels. If a DUTGND
input is required for each channel, the user can configure the GUARDINx/DUTGNDx pins as DUTGND inputs for
each PMU channel.
This pin has a pull-down current source (~350 μA). In LVDS interface mode, the CPOHx and CPOLx pins default
to differential interface pins.
Open-Drain Output for Guard and Clamp Alarms. This open-drain pin provides shared alarm information
about the guard amplifier and clamp circuitry. By default, this output pin is disabled. The system control
register allows the user to enable this function and to set the open-drain output as a latched output. The user
can also choose to enable alarms for the guard amplifier, the clamp circuitry, or both. When this pin flags an
alarm, the origins of the alarm can be determined by reading back the alarm status register. Two flags per
channel in this word (one latched, one unlatched) indicate which function caused the alarm and whether the
alarm is still present.
Open-Drain Output for Temperature Alarm. This latched, active low, open-drain output flags a temperature
alarm to indicate that the junction temperature has exceeded the default temperature setting (130°C) or the
user programmed temperature setting. Two flags in the alarm status register (one latched, one unlatched)
indicate whether the temperature has dropped below 130°C or remains above 130°C. User action is required
to clear this latched alarm flag by writing to the clear bit (Bit 6) in any of the PMU registers.
Digital Reset Input. This active low, level sensitive input resets all internal nodes on the device to their power-
on reset values.
Force Output for High Current Range (Channel 0). Use an external resistor at this pin for current ranges up to
±80 mA. For more information, see the Current Range Selection section.
Rev. D | Page 18 of 64