Programming in the Mnemonic Display Mode
Editing Programs
Changing an Instruction
Inserting an Instruction
1, 2, 3...
1, 2, 3...
Move the cursor to the instruction column to insert or delete an instruction. In-
structions cannot be inserted or deleted when the cursor is at an operand.
It is not necessary to store a program after it is edited in the mnemonic display
mode. The edited program will be automatically stored on the work disk. Always
use the check program operation to avoid storing incorrect programs.
If function codes or any other input method that requires pressing the Enter Key
is used while inserting an instruction, you will leave the Insert mode and will have
to enter the Write mode to complete the instruction.
Instructions can be inserted down to the last line of the display. At the bottom of
the display, press the PgDn Key to display the next page before inserting further
instructions.
1. Press the F1 or F2 Key in the Read or Insert mode to select the Write mode.
2. Move the cursor to the instruction to be changed, enter the new instruction
1. Press the F2 Key in the Read or Write mode to select the Insert mode.
2. Move the cursor to the position where the instruction is to be inserted, enter
and press the Enter Key.
the instruction and press the Enter Key.
The instruction will be inserted at the cursor position and subsequent lines of
the original program will move down. The cursor will move to the position of
the original instruction.