Entering Conditions on the
Ladder Diagram
Programming in Ladder Form
Entering Other Instructions
78
LD
AND
LD NOT
AND NOT
OR
OR NOT
Immediate update
instruction
Differentiate up
instruction
Differential down
instruction
Instruction
Symbol
Note I/O names can be used instead of the bit addresses. Mnemonics can be input in
!
j
i
Instructions can be entered using the function keys or using the mnemonics for
the instructions. When inputting mnemonics, set the program input mode to CV
mode. Mnemonics cannot be input in C mode.
I/O names can be input instead of bit addresses, provided the bit address has
already been allocated an I/O name using the Edit I/O name operation (see 4-1
Editing I/O Names ).
In the following table, items in parentheses are not required when inputting the
program in C mode, but are required when inputting in CV mode.
either upper-case or lower-case letters. Refer to page 113 for information on in-
putting OR, LD, AND, and LD. The F7 Key need not be input in C mode.
To enter basic righthand instructions, move the cursor to the right of the right-
most input. A break will appear in the connecting line if an output is entered when
the cursor is not to the right of the rightmost input. Use the line connect opera-
tions (see page 82) to rejoin the connection if this problem occurs.
The number of condition permitted on any line depends on the number of oper-
ands for the righthand instruction. If it is not possible to enter all conditions on a
single line, use the continue operation to join the line to the next line. Refer to
page 85 for information on the continue operation.
Instructions can be entered with the function keys or as mnemonics. When in-
putting mnemonics, set the program input mode to CV mode. Mnemonics can-
not be input in C mode.
I/O names can be input instead of bit addresses, word addresses, or timer/
counter numbers, provided the I/O names have been allocated using the Edit I/O
name operations (see 4-1 Editing I/O Names ).
3. Enter the bit address for the condition and press the Enter Key.
(F7) Bit_address CR
Shift+F7 Bit_address
CR
F8 Bit_address CR
Shift+F8 Bit_address
CR
Instruction Bit_address
Shift+F10 CR
Instruction Bit_address
Shift+F3 CR
Instruction Bit_address
Shift+F4 CR
Function key inputs
L D _ Bit_address CR
A N D _ Bit_address CR
L D _ N O T _
Bit_address CR
A N D _ N O T _
Bit_address CR
O R _ Bit_address CR
O R _ N O T _
Bit_address CR
Instruction _ Bit_address
Shift+F10 CR
Instruction _ Bit_address
Shift+F3 CR
Instruction _ Bit_address
Shift+F4 CR
Mnemonic inputs
–––
LD NOT and AND NOT
can also be input using
the Slash (/) Key: (F7) /
Bit_address CR.
–––
OR NOT can also be
input using the Slash (/)
Key: F8 / Bit_address
CR.
To set both the
immediate update (!) and
differentiate instructions,
enter them
consecutively.
However, only the
immediate update (!) is
available with the NOT
instructions. The
differentiate instructions
cannot be used.
Remarks
Section 3-5