Editing Network Support Tables
Communication with a C-series PCs
Editing Routing Tables
Editing Local Network Tables
182
In the example shown above, the computer connected to the PC in network 1
can communicate with PCs on networks 2 or 3. It cannot communicate with the
PCs on network 4, which is the 4th level of communications.
The CV pack is intended for operation of CV Series PC’s only. Therefore, C Se-
ries PC’s cannot be operated via the networks, except for the I/O monitor opera-
tions which can be used with C Series PC’s on the SYSMAC LINK network.
CV Series PC’s cannot operate a PC through the network if the SYSMAC LINK
unit for the PC is set to C mode.
To edit the routing tables, select “E:Edit routing table” from the Routing Table
menu. The local network table will appear (see below) and a message at the
top-right of the screen will indicate that the routing table is being edited.
The following function keys can be used during editing operations.
Set the items shown in the following table. Use the Up, Down, Left, Right Keys to
move the cursor to the required positions on the screen.
Press the PgDn Key to display the relay network table editing screen (see next
diagram).
F1 (Net #)
F10 (end)
Loc Netwk
SIOU unit #
Function key
Item
Sets or changes the number of networks when editing the local
networks or relay networks.
Input the F1 Key, number_of_networks , and Enter Key.
The number of networks can be set to a maximum of 16 local
networks or 20 relay networks.
Press the F10 Key after creating data on the screen to save the
data and return to the Routing Table Menu. Always press the F10
Key to save the routing table after creating data.
Set the network address of each CPU Bus Unit mounted to the
PC. Set the network addresses in the range 1 to 127.
Make sure that the same network address is not input twice.
Press the Insert Key to insert a network address or the Delete
Key to delete a network address.
Set the unit number of each CPU Bus Unit mounted to the PC.
Set the unit numbers in the range 0 to 15.
Make sure that the same unit number is not set twice.
Setting method
Function
Section 4-6