Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Customization
Creating Data Areas
242
Note Once custom data areas have been set, the words and bits in them must always
When finished, move the cursor to the confirmation area and press the Enter
Key. If the same prefix is used for more than one area, an error message will
appear and you will have to redesignate the prefix.
The CIO Area from CIO 0000 to CIO 2555 can be broken up into up to 18 custom
data areas with area prefixes. To create custom data area, select “G:Word
Grouping.” The following display will appear.
be addressed using the assigned prefixes.
Press the F2 Key to enable inputting and then specify the abbreviation (prefix)
and word range for each custom data area. The prefixes can be only one charac-
ter and cannot be the same as prefixes used for other data areas.
Custom areas must be set in order beginning from No. 1 on the display and must
be set so that words do not overlap between the areas. The smaller address in
each range must be specified first.
The Ins Key can be pressed to open up the current line and move all setting
down one line. The Del Key can be pressed to delete the data at the current cur-
sor position.
When you have finished setting data areas and prefixes, press the F10 Key and
then press the Enter Key to confirm. The settings will be checked for errors. If the
check finds no mistakes, press the Enter Key to return to the Customize menu. If
an error display appears, press the Enter Key to return to the input display for
function codes and correct the mistake. Possible errors are shown in the follow-
ing table.