CRT1-OD16TAH Omron, CRT1-OD16TAH Datasheet - Page 410

no-image

CRT1-OD16TAH

Manufacturer Part Number
CRT1-OD16TAH
Description
16 Out NPN 3 Tier
Manufacturer
Omron
Datasheet

Specifications of CRT1-OD16TAH

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Temperature Input Units
Setting Using the CX-
Integrator
Temperature Ranges
by Input Type
CRT1-TS04T
386
1,2,3...
Note
CRT1-TS04P
1. Always set pin 5 and pin 7 to OFF (default).
2. Always set pin 8 to ON if the DIP switch is used to set the ranges. If this pin
3.
4. °C/°F display settings cannot be set individually for each input.
Input types can be set for each temperature input using the CX-Integrator.
Use the following procedure.
1. Turn ON the power supply to the Temperature Input Unit.
2. Double-click the icon of the Temperature Input Unit to be set in the Network
3. Click the tab for the input where the input type is to be set and select an
4. Return to the General Tab Page, click the Transfer [PC to Unit] Button to
5. Click the OK Button and exit the window.
The following tables show the temperature ranges for each input type.
R
S
K (−200 to 1300°C)
Always
OFF
SW1
Note If the settings are incorrect, the MS Indicator will flash red and the
is OFF, the DIP switch settings will not be enabled.
The DIP switch settings are read when the power is turned ON.
Configuration Window or right-click the icon and select Parameter - Edit.
The Configuration Window will be displayed.
input type in the Input Type Field.
download the data, and then click the Reset Button to reset the Unit.
Input type
Unit will not operate. In this case, make the settings again and reset
the power supply.
OFF
ON
SW2
0 to 1,700
0 to 1,700
−200 to 1,300
Temperature range (°C)
Always OFF.
SW3
SW4
PT100 (−200 to 850°C)
0 to 3,000
0 to 3,000
−300 to 2,300
PT100 (−200 to 200°C)
Temperature range (°F)
Input type
Section 7-5

Related parts for CRT1-OD16TAH