E39-C1 Omron, E39-C1 Datasheet - Page 10

E3MC CABLE CONNECTOR 2M

E39-C1

Manufacturer Part Number
E39-C1
Description
E3MC CABLE CONNECTOR 2M
Manufacturer
Omron
Type
Threaded Cylindrical Photoelectric Sensorsr
Datasheets

Specifications of E39-C1

Features
Axial and Radial types
Sensing Distance
7 mm
Amplifier Type
Built In Amplifier
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3MC
1-output Models (E3MC-A@@/E3MC-X@@/E3MC-Y@@)
1. Bank Selection
Set the Mode Selector to the TEACH mode and then select the
BANK using the SELECT button.
2. Color Registration
3. Threshold Adjustment (If Required)
Press the SELECT button in ADJ mode with or without the sens-
ing object located at the detection point. The bank selected in the
TEACH mode or RUN mode will become the bank for the ADJ
mode.
4. Operation
The detection operation is performed in RUN mode. The regis-
tered color is selected with bank selection input.
10
Settings
Locate the registered object at the detection
point and press the TEACH button.
Sensing object
Sensor
Registered object
Sensor
No Good
OK
All the red threshold indicators
will flash if registration has not
been completed.
Refer to Technical Guide on
page 12.
Detection Level and Tolerance
As the detected color becomes closer to the registered color, the
number of lit detection level indicators increase. The control out-
put of the E3MC will be ON if the detection level exceeds the
threshold level and OFF if the detection level does not exceed the
threshold level provided that the E3MC is in conformity output
mode.
Set the threshold to a higher level for highly-precise color discrim-
ination and to a lower level to ignore minor tint differences or dirt
retention.
Operation
indicator: ON
Control output:
ON
Detection level
Threshold
value
Tolerance
All the detection level
indicators are ON.
The threshold is set to 4.
Operation
indicator: OFF
Control output:
OFF
Detection level
E3MC
Threshold
value

Related parts for E39-C1