E39-C1 Omron, E39-C1 Datasheet - Page 14

E3MC CABLE CONNECTOR 2M

E39-C1

Manufacturer Part Number
E39-C1
Description
E3MC CABLE CONNECTOR 2M
Manufacturer
Omron
Type
Threaded Cylindrical Photoelectric Sensorsr
Datasheets

Specifications of E39-C1

Features
Axial and Radial types
Sensing Distance
7 mm
Amplifier Type
Built In Amplifier
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3MC
The following is an example of ladder programming.
The following is an example of a timing chart of teaching after bank selection.
Function 3: Remote control of threshold adjustments
through the PLC or PT
Input either one of the following signals as remote control input.
There will be an answer-back output for 0.3 s if the signal is cor-
rectly accepted.
Threshold and Display
14
6
7
8
9
10
11
12
No.
Remote control input
Answer-back output
00100
00000
END
Control signal
OFF
OFF
ON
ON
TIM000
Operates in
bank 2.
Threshold 1
Threshold 2
Threshold 3
Threshold 4
Threshold 5
Threshold 6
Threshold 7
Input detection.
00100
#XXXX
TIM000
Threshold 1 selected.
Threshold 2 selected.
Threshold 3 selected.
Threshold 4 selected.
Threshold 5 selected.
Threshold 6 selected.
Threshold 7 selected.
All E3MC models
Bank 1 designated.
TIM000 set value
No.1: 0003
No.2: 0006
No.3: 0009
No.4: 00012
No.5: 00015
Input: 00000
Output: 00100
Others: Work bits
Bank
select-
ing.
An interval of
0.6 s min.
Sensing
restarts.
Input detection.
Answer-back output with
normal signal reception.
The following is an example of ladder programming for setting
control signals. Full control of the E3MC is possible using this
function together with function 2.
Note: 1. The permissible error of each signal pulse is ±0.1 s max.
Teaching specified
in bank 1.
05000
05001
05002
05002
00000
T000
T001
05000
2. A minimum interval of 0.6 s is required between signals.
3. Threshold 4 is set after teaching.
END
Teach-
ing.
TIM000
TIM001
TIM002
Answer-back output with teaching OK.
(No output if teaching fails.)
05000
TIM000
#XXXX
05001
TIM001
#YYYY
05002
TIM002
#ZZZZ
00100
Sensing
restarts
TIM000, TIM001, TIM002
set values
No.1: (0000, 0000, 0003)
No.2: (0000, 0000, 0006)
No.3: (0000, 0000, 0009)
No.4: (0000, 0000, 00012)
No.5: (0000, 0000, 00015)
No.6: (0003, 0003, 0003)
No.7: (0003, 0006, 0003)
No.8: (0003, 0009, 0003)
No.9: (0003, 0003, 0006)
No.10: (0003, 0006, 0006)
No.11: (0003, 0003, 0009)
No.12: (0006, 0003, 0003)
Input: 00000
Output: 00100
Others: Work bits
(XXXX, YYYY, ZZZZ)
E3MC

Related parts for E39-C1