ADV601LCJST Analog Devices Inc, ADV601LCJST Datasheet - Page 26

no-image

ADV601LCJST

Manufacturer Part Number
ADV601LCJST
Description
IC CODEC VIDEO DSP/SRL 120LQFP
Manufacturer
Analog Devices Inc
Type
Video Codecr
Datasheet

Specifications of ADV601LCJST

Rohs Status
RoHS non-compliant
Data Interface
DSP, Serial
Resolution (bits)
8 b
Sigma Delta
No
Voltage - Supply, Analog
4.5 V ~ 5.5 V
Voltage - Supply, Digital
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
120-LQFP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADV601LCJST
Manufacturer:
AD
Quantity:
1 831
Part Number:
ADV601LCJST
Manufacturer:
AD
Quantity:
1 045
Part Number:
ADV601LCJST
Manufacturer:
ST
0
Part Number:
ADV601LCJSTZ
Manufacturer:
ADI
Quantity:
200
Part Number:
ADV601LCJSTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADV601LCJSTZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADV601LC
Code Name
#SOF1
#SOF2
<VITC>
<TYPE1>
<TYPE2>
<TYPE3>
<TYPE4>
#SOB1
#SOB2
#SOB3
#SOB4
#SOB5
Code
0xffffffff40000000
0xffffffff41000000
(96 bits)
0x81
0x82
0x83
0x84
0xffffffff81
0xffffffff82
0xffffffff83
0xffffffff84
0xffffffff8f
Table XV. ADV601LC Field and Block Delimiters (Codes)
Description (Align all #Delimiter Codes to 32-Bit Boundaries)
Start of Field delimiter identifies Field1 data. #SOF1 resets the Huffman decoder and
is sufficient on its own to reset the processing of the chip during decode. Please note
that this code or #SOF2 are the only delimiters necessary between adjacent fields.
#SOF1 operates identically to #SOF2 except that during decode it can be used to
differentiate between Field1 and Field2 in the generation of the Field signal (master
mode) and/or SAV/EAV codes for CCIR-656 modes.
Start of Field delimiter identifies Field2 data. #SOF resets the Huffman decoder and
is sufficient on its own to reset the processing of the chip during decode. Please note
that this code or #SOF1 are the only delimiters necessary between adjacent fields.
#SOF2 operates identically to #SOF1 except that during decode it can be used to
differentiate between Field2 and Field1 in the generation of the Field signal (master
mode) and/or SAV/EAV codes for CCIR-656 modes.
This is a 12-byte string of data extracted by the video interface during encode opera-
tions and inserted by the video interface into the video data during decode operations.
The data content is 90 bits in length. For a complete description of VITC format, see
pages 175-178 of Video Demystified: A Handbook For The Digital Engineer (listed in
References section).
This is an 8-bit delimiter-less type code for the first sub-band block of wavelet data.
(Model 1 Chroma)
This is an 8-bit delimiter-less type code for the first sub-band block of wavelet data.
(Model 1 Luma)
This is an 8-bit delimiter-less type code for the first sub-band block of wavelet data.
(Model 2 Chroma)
This is an 8-bit delimiter-less type code for the first sub-band block of wavelet data.
(Model 2 Luma)
Start of Block delimiter identifies the start of Huffman coded sub-band data. This
delimiter will reset the Huffman decoder if a system ever experiences bit errors or gets
out of sync. The order of blocks in the frame is fixed and therefore implied in the bit
stream and no unique #SOB delimiters are needed per block. There are 41 #SOB
delimiters and associated BW and Huffman data within a field. #SOB1 is differenti-
ated from #SOB2, #SOB3 and #SOB4 in that they indicate which model and
Huffman table was used in the Run Length Coder for the particular block:
#SOB1 Model 1 Chroma
#SOB2 Model 1 Luma
#SOB3 Model 2 Chroma
#SOB4 Model 2 Luma
#SOB5 Zero data block. All data after this delimiter and before the next start of block
delimiter is ignored (if present at all) and assumed zero including the BW value.
–26–
REV. 0