EPM9560RC208-20 Altera, EPM9560RC208-20 Datasheet - Page 35

EPM9560RC208-20

Manufacturer Part Number
EPM9560RC208-20
Description
Manufacturer
Altera
Datasheet

Specifications of EPM9560RC208-20

Family Name
MAX 9000
Memory Type
EEPROM
# Macrocells
560
Number Of Usable Gates
12000
Frequency (max)
100MHz
Propagation Delay Time
20ns
Number Of Logic Blocks/elements
35
# I/os (max)
153
Operating Supply Voltage (typ)
5V
In System Programmable
Yes
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
208
Package Type
RQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9560RC208-20
Manufacturer:
ALTERA
0
Part Number:
EPM9560RC208-20C
Manufacturer:
ALTERA
0
Part Number:
EPM9560RC208-20N
Manufacturer:
ALTERA
0
Notes to tables:
(1)
(2)
(3)
(4)
(5)
(6)
Power
Consumption
Altera Corporation
t
t
t
t
t
t
t
t
Symbol
LOCAL
ROW
COL
DIN_D
DIN_CLK
DIN_CLR
DIN_IOC
DIN_IO
Table 24. Interconnect Delays
These values are specified under the MAX 9000 device recommended operating conditions, shown in
page
See
delays.
This parameter is a guideline that is sample-tested only. It is based on extensive device characterization. This
parameter applies for both global and array clocking as well as both macrocell and I/O cell registers.
Measured with a 16-bit loadable, enabled, up/down counter programmed in each LAB.
The t
The t
or timing analysis is required to determine actual worst-case performance.
Application Note 77 (Understanding MAX 9000 Timing)
ROW ,
27.
LPA
LAB local array delay
FastTrack row delay
FastTrack column delay
Dedicated input data delay
Dedicated input clock delay
Dedicated input clear delay
Dedicated input I/O register
clock delay
Dedicated input I/O register
control delay
parameter must be added to the t
t
COL,
Parameter
and t
IOC
delays are worst-case values for typical applications. Post-compilation timing simulation
The supply power (P) versus frequency (f
be calculated with the following equation:
P = P
The P
and switching frequency, can be calculated using the guidelines given in
Application Note 74 (Evaluating Power for Altera
depends on the switching frequency and the application logic.
The I
I
CCINT
CCINT
INT
IO
(6)
(6)
value, which depends on the device output load characteristics
+ P
= (A
value is calculated with the following equation:
IO
Conditions
= I
f
LOCAL
MAX
CCINT
MAX 9000 Programmable Logic Device Family Data Sheet
MC
parameter for macrocells running in low-power mode
TON
tog
for more information on test conditions for t
V
) + [B
LC
CC
Min
)
+ P
-10
IO
(MC
Max
0.5
0.9
0.9
4.0
2.7
4.5
2.5
5.5
DEV
MAX
Speed Grade
Min
– MC
) for MAX 9000 devices can
-15
Devices). The I
TON
Max
0.5
1.4
1.7
4.5
3.5
5.0
3.5
6.0
)] + (C MC
Min
-20
CCINT
PD1
Max
Table 15 on
0.5
2.0
3.0
5.0
4.0
5.5
4.5
6.5
USED
and t
value
Unit
ns
ns
ns
ns
ns
ns
ns
ns
PD2
.
35

Related parts for EPM9560RC208-20