C8051F317-GMR Silicon Laboratories Inc, C8051F317-GMR Datasheet - Page 151

no-image

C8051F317-GMR

Manufacturer Part Number
C8051F317-GMR
Description
MCU 8-Bit C8051F31x 8051 CISC 16KB Flash 3.3V 24-Pin QFN EP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051F317-GMR

Package
24QFN EP
Device Core
8051
Family Name
C8051F31x
Maximum Speed
25 MHz
Ram Size
1.25 KB
Program Memory Size
16 KB
Operating Supply Voltage
3.3 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
21
Interface Type
I2C/SMBus/SPI/UART
On-chip Adc
17-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F317-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
C8051F317-GMR
Quantity:
1 500
Company:
Part Number:
C8051F317-GMR
Quantity:
398
Figure 14.4 shows the typical SCL generation described by Equation 14.2. Notice that T
twice as large as T
extended low by slower slave devices, or driven low by contending master devices). The bit rate when
operating as a master will never exceed the limits defined by equation Equation 14.1.
Setting the EXTHOLD bit extends the minimum setup and hold times for the SDA line. The minimum SDA
setup time defines the absolute minimum time that SDA is stable before SCL transitions from low-to-high.
The minimum SDA hold time defines the absolute minimum time that the current SDA value remains stable
after SCL transitions from high-to-low. EXTHOLD should be set so that the minimum setup and hold times
meet the SMBus Specification requirements of 250 ns and 300 ns, respectively. Table 14.2 shows the min-
imum setup and hold times for the two EXTHOLD settings. Setup and hold time extensions are typically
necessary when SYSCLK is above 10 MHz.
With the SMBTOE bit set, Timer 3 should be configured to overflow after 25 ms in order to detect SCL low
timeouts (see
to reload while SCL is high, and allow Timer 3 to count when SCL is low. The Timer 3 interrupt service rou-
tine should be used to reset SMBus communication by disabling and re-enabling the SMBus.
SMBus Free Timeout detection can be enabled by setting the SMBFTE bit. When this bit is set, the bus will
be considered free if SDA and SCL remain high for more than 10 SMBus clock source periods (see
Figure 14.4). When a Free Timeout is detected, the interface will respond as if a STOP was detected (an
interrupt will be generated, and STO will be set).
Timer Source
Overflows
SCL
*Note: Setup Time for ACK bit transmissions and the MSB of all data transfers. The s/w
EXTHOLD
Section “14.3.3. SCL Low Timeout” on page
delay occurs between the time SMB0DAT or ACK is written and when SI is cleared.
Note that if SI is cleared in the same write that defines the outgoing ACK value, s/w
delay is zero.
0
1
LOW
Table 14.2. Minimum SDA Setup and Hold Times
T
. The actual SCL output may vary due to other devices on the bus (SCL may be
Low
Figure 14.4. Typical SMBus SCL Generation
Minimum SDA Setup Time
1 system clock + s/w delay*
T
low
11 system clocks
– 4 system clocks
T
High
OR
Rev. 1.7
C8051F310/1/2/3/4/5/6/7
148). The SMBus interface will force Timer 3
Minimum SDA Hold Time
12 system clocks
3 system clocks
SCL High Timeout
HIGH
is typically
151

Related parts for C8051F317-GMR