AT32UC3B0512AU Atmel Corporation, AT32UC3B0512AU Datasheet - Page 68

no-image

AT32UC3B0512AU

Manufacturer Part Number
AT32UC3B0512AU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3B0512AU

Flash (kbytes)
512 Kbytes
Pin Count
64
Max. Operating Frequency
60 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
44
Ext Interrupts
44
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
4
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
96
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B0512AU-Z2U
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
9.6.17
Name:
Access Type:
Offset:
Reset Value:
• KEY: Register Write protection
• FCD: BOD Fuse calibration done
• CTRL: BOD Control
• HYST: BOD Hysteresis
• LEVEL: BOD Level
32059L–AVR32–01/2012
31
23
15
7
-
-
-
• This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
• Set to 1 when CTRL, HYST and LEVEL fields has been updated by the Flash fuses after power-on reset or Flash fuses
• 0: Allow subsequent overwriting of the value by Flash fuses.
• 1: The CTRL, HYST and LEVEL values will not be updated again by Flash fuses.
• 0: BOD is off.
• 1: BOD is enabled and can reset the chip.
• 2: BOD is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR
• 3: BOD is off.
• 0: No hysteresis
• 1: Hysteresis On
• This field sets the triggering threshold of the BOD. See Electrical Characteristics for actual voltage levels.
• Note that any change to the LEVEL field of the BOD register should be done with the BOD deactivated to avoid spurious reset
update.
register.
or interrupt.
BOD Level Register
HYST
30
22
14
BOD
Read/Write
0x0D0
-
6
-
-
29
21
13
5
-
-
28
20
12
4
-
-
KEY
27
19
11
3
-
-
LEVEL
26
18
10
2
-
-
25
17
9
1
-
CTRL
FCD
24
16
8
0
68