2.9.4. Emulator Trace Window
Once the trace enable button in the emulator control window is selected the
emulator trace window (shown below) is loaded.
The trace window is made up of the following components.
Reset Button
Read Button
Note : in fact the Read Button is not needed anymore, because actually, if tracing is
active, the trace buffer will be automatically updated as soon as the emulator stops.
Address value
Trace Mode selection
This option list enables the user to chose between the two trace modes. The first
mode fills the trace memory and stops, generating a trace break. This enables to
record the first instruction of an execution. In the second mode, when the trace
memory is full, the Emulator resets the trace address and refills the memory again ;
This button reset the trace memory.
Uploads the trace buffer contents from the in-circuit emulator
This value is the address of the trace memory.
Fig. 19 The trace buffer window