ST72F264G ST Microelectronics, ST72F264G Datasheet - Page 108

no-image

ST72F264G

Manufacturer Part Number
ST72F264G
Description
(ST72F260G - ST72F264G) 8-BIT MCU
Manufacturer
ST Microelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST72F264G1B5
Manufacturer:
ST
0
Part Number:
ST72F264G1M6
Manufacturer:
ST
0
Part Number:
ST72F264G2B5
Manufacturer:
ST
0
Part Number:
ST72F264G2B5
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72F264G2B6
Manufacturer:
ST
Quantity:
10
Part Number:
ST72F264G2B6
Manufacturer:
NEC
Quantity:
6 097
Part Number:
ST72F264G2B6
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72F264G2H
Manufacturer:
ST
0
Part Number:
ST72F264G2H1
Manufacturer:
CMD
Quantity:
1 020
Part Number:
ST72F264G2H1
Manufacturer:
ST
0
Part Number:
ST72F264G2H1
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72F264G2H1E
Manufacturer:
ST
Quantity:
50 000
Part Number:
ST72F264G2H1E
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72F264G2M6
Manufacturer:
SCS
Quantity:
1 225
Part Number:
ST72F264G2M6
Manufacturer:
ST
Quantity:
20 000
www.DataSheet4U.com
DataSheet
ST72260G, ST72262G, ST72264G
I
Bit 1 = M/SL Master/Slave.
This bit is set by hardware as soon as the interface
is in Master mode (writing START=1). It is cleared
by hardware after detecting a Stop condition on
the bus or a loss of arbitration (ARLO=1). It is also
cleared when the interface is disabled (PE=0).
0: Slave mode
1: Master mode
Bit 0 = SB Start bit (Master mode).
This bit is set by hardware as soon as the Start
condition
START=1). An interrupt is generated if ITE=1. It is
cleared by software reading SR1 register followed
by writing the address byte in DR register. It is also
cleared by hardware when the interface is disa-
bled (PE=0).
0: No Start condition
1: Start condition generated
I
Read Only
Reset Value: 0000 0000 (00h)
Bit 7:5 = Reserved. Forced to 0 by hardware.
Bit 4 = AF Acknowledge failure .
This bit is set by hardware when no acknowledge
is returned. An interrupt is generated if ITE=1. It is
cleared by software reading SR2 register or by
hardware when the interface is disabled (PE=0).
The SCL line is not held low while AF=1.
0: No acknowledge failure
1: Acknowledge failure
Bit 3 = STOPF Stop detection (Slave mode).
This bit is set by hardware when a Stop condition
is detected on the bus after an acknowledge (if
ACK=1). An interrupt is generated if ITE=1. It is
cleared by software reading SR2 register or by
hardware when the interface is disabled (PE=0).
The SCL line is not held low while STOPF=1.
0: No Stop condition detected
1: Stop condition detected
108/171
2
2
C BUS INTERFACE (Cont’d)
C STATUS REGISTER 2 (SR2)
7
0
4
U
.com
0
is
0
generated
AF
STOPF ARLO BERR GCAL
(following
www.DataSheet4U.com
a
write
0
Bit 2 = ARLO Arbitration lost .
This bit is set by hardware when the interface los-
es the arbitration of the bus to another master. An
interrupt is generated if ITE=1. It is cleared by soft-
ware reading SR2 register or by hardware when
the interface is disabled (PE=0).
After an ARLO event the interface switches back
automatically to Slave mode (M/SL=0).
The SCL line is not held low while ARLO=1.
0: No arbitration lost detected
1: Arbitration lost detected
Bit 1 = BERR Bus error.
This bit is set by hardware when the interface de-
tects a misplaced Start or Stop condition. An inter-
rupt is generated if ITE=1. It is cleared by software
reading SR2 register or by hardware when the in-
terface is disabled (PE=0).
The SCL line is not held low while BERR=1.
0: No misplaced Start or Stop condition
1: Misplaced Start or Stop condition
Bit 0 = GCAL General Call (Slave mode).
This bit is set by hardware when a general call ad-
dress is detected on the bus while ENGC=1. It is
cleared by hardware detecting a Stop condition
(STOPF=1) or when the interface is disabled
(PE=0).
0: No general call address detected on bus
1: general call address detected on bus
www.DataSheet
www.DataSheet
www.DataSheet
www.DataSheet4U
4U
4U.com
4U
.com
.com
.com

Related parts for ST72F264G