mc68hc908gr8b Freescale Semiconductor, Inc, mc68hc908gr8b Datasheet - Page 141

no-image

mc68hc908gr8b

Manufacturer Part Number
mc68hc908gr8b
Description
M68hc08 Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet
Fast Data Tolerance
Figure 13-9
or a framing error. The fast stop bit ends at RT10 instead of RT16 but is still there for the stop bit data
samples at RT8, RT9, and RT10.
For an 8-bit character, data sampling of the stop bit takes the receiver 9 bit times
+ 10 RT cycles = 154 RT cycles.
With the misaligned character shown in
the count of the transmitting device is 10 bit times
The maximum percent difference between the receiver count and the transmitter count of a fast 8-bit
character with no errors is
For a 9-bit character, data sampling of the stop bit takes the receiver 10 bit times
+ 10 RT cycles = 170 RT cycles.
With the misaligned character shown in
the count of the transmitting device is 11 bit times
The maximum percent difference between the receiver count and the transmitter count of a fast 9-bit
character with no errors is
13.4.3.6 Receiver Wakeup
So that the MCU can ignore transmissions intended only for other receivers in multiple-receiver systems,
the receiver can be put into a standby state. Setting the receiver wakeup bit, RWU, in SCC2 puts the
receiver into a standby state during which receiver interrupts are disabled.
Depending on the state of the WAKE bit in SCC1, either of two conditions on the PTE1/RxD pin can bring
the receiver out of the standby state:
Freescale Semiconductor
Address mark — An address mark is a 1 in the most significant bit position of a received character.
When the WAKE bit is set, an address mark wakes the receiver from the standby state by clearing
the RWU bit. The address mark also sets the SCI receiver full bit, SCRF. Software can then
compare the character containing the address mark to the user-defined address of the receiver. If
they are the same, the receiver remains awake and processes the characters that follow. If they
are not the same, software can set the RWU bit and put the receiver back into the standby state.
shows how much a fast received character can be misaligned without causing a noise error
RECEIVER
RT CLOCK
MC68HC908GR8B Data Sheet, Rev. 3.0
Figure
Figure
170 176
------------------------- -
154 160
------------------------- -
STOP
Figure 13-9. Fast Data
170
154
13-9, the receiver counts 154 RT cycles at the point when
13-9, the receiver counts 170 RT cycles at the point when
100
100
16 RT cycles = 160 RT cycles.
16 RT cycles = 176 RT cycles.
SAMPLES
DATA
=
=
3.53%
3.90%
·
IDLE OR NEXT CHARACTER
16 RT cycles
16 RT cycles
Functional Description
141