tmp89cm42 TOSHIBA Semiconductor CORPORATION, tmp89cm42 Datasheet - Page 98

no-image

tmp89cm42

Manufacturer Part Number
tmp89cm42
Description
8 Bit Microcontroller Tlcs-870/c1 Series
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
7.3
Function
RB000
7.3.3
7.3.4
checked by reading VDCR1<VDxF> and VDCR1<VDxSF>.
(VDxLVL), VDCR1<VDxF> is set to "1" and is held in this state. VDCR1<VDxF> is not cleared to "0" when
the supply voltage (VDD) becomes equal to or higher than the detection voltage (VDxLVL).
To clear VDCR1<VDxF>, "0" must be written to it.
(VDxLVL), VDCR1<VDxSF> is set to "1". When the supply voltage (VDD) becomes equal to or higher than
the detection voltage (VDxLVL), VDCR1<VDxSF> is cleared to "0".
Selecting the detection voltage level
Voltage detection flag and voltage detection status flag
Note 1: When the supply voltage (VDD) becomes lower than the detection voltage (VDxLVL) in the STOP, IDLE0 or
Note 2: Depending on the voltage detection timing, the voltage detection status flag (VDxSF) may be changed earlier
Select a detection voltage at VDCR1<VDxLVL>.
The magnitude relation between the supply voltage (VDD) and the detection voltage (VDxLVL) can be
If VDCR2<VDxEN> is set at "1", when the supply voltage (VDD) becomes lower than the detection voltage
When VDCR2<VDxEN> is cleared to "0" after VDCR1<VDxF> is set to "1", the previous state is still held.
If VDCR2<VDxEN> is set at "1", when the supply voltage (VDD) becomes lower than the detection voltage
Unlike VDCR1<VDxF>, VDCR1<VDxSF> does not hold the set state.
Voltage detection reset signal
detection reset signal is generated continuously as long as the supply voltage (VDD) is lower than the
detection voltage (VDxLVL).
SLEEP0 mode, the voltage detection flag and the voltage detection status flag are changed after the oper-
ation mode is returned to NORMAL or SLOW mode.
than the voltage detection flag (VDxF) by a maximum of 2/fcgck[s].
Detection voltage level
VDCR1 and VDCR2 are initialized by a power-on reset or an external reset input only. A voltage
VDCR2<VDxEN>
VDD level
Figure 7-3 Voltage Detection Reset Signal
Page 84
TMP89CM42

Related parts for tmp89cm42