at32uc3b0512-z2ues ATMEL Corporation, at32uc3b0512-z2ues Datasheet - Page 329

no-image

at32uc3b0512-z2ues

Manufacturer Part Number
at32uc3b0512-z2ues
Description
32-bit Avr Microcontroller
Manufacturer
ATMEL Corporation
Datasheet
21.6.5.1
21.6.5.2
32059J–12/2010
IrDA Modulation
IrDA Baud Rate
• Configure the TXD pin as I/O and set it as an output at 0 (to avoid LED emission). Disable the
• Receive data
For baud rates up to and including 115.2 Kbits/sec, the RZI modulation scheme is used. “0” is
represented by a light pulse of 3/16th of a bit time. Some examples of signal pulse duration are
shown in
Table 21-10. IrDA Pulse Duration
Figure 21-33
Figure 21-33. IrDA Modulation
Table 21-11
the requirement on the maximum acceptable error of ±1.87% must be met.
Table 21-11. IrDA Baud Rate Error
Baud Rate
2.4 Kb/s
9.6 Kb/s
19.2 Kb/s
38.4 Kb/s
57.6 Kb/s
115.2 Kb/s
Peripheral Clock
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
internal pull-up (better for power consumption).
Table
gives some examples of CD values, baud rate error and pulse duration. Note that
shows an example of character transmission.
Transmitter
21-10.
Output
TXD
Baud Rate
115 200
115 200
115 200
115 200
57 600
57 600
57 600
Bit Period
Start
Bit
0
1
0
Pulse Duration (3/16)
78.13 µs
19.53 µs
9.77 µs
4.88 µs
3.26 µs
1.63 µs
CD
11
18
22
22
36
1
2
4
Data Bits
0
0
Baud Rate Error
1
0.00%
1.38%
1.25%
1.38%
0.00%
1.38%
1.25%
1
16
3
0
Bit Period
AT32UC3B
Stop
Bit
1
Pulse Time
1.63
1.63
1.63
1.63
3.26
3.26
3.26
329