c8051t617 Silicon Laboratories, c8051t617 Datasheet - Page 176

no-image

c8051t617

Manufacturer Part Number
c8051t617
Description
Mixed Signal Byte-programmable Eprom Mcu
Manufacturer
Silicon Laboratories
Datasheet
C8051T610/1/2/3/4/5/6/7
SFR Definition 18.3. CKCON: Clock Control
176
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bits1–0: SCA1-SCA0: Timer 0/1 Prescale Bits.
T3MH
R/W
Bit7
T3MH: Timer 3 High Byte Clock Select.
This bit selects the clock supplied to the Timer 3 high byte if Timer 3 is configured in split 8-
bit timer mode. T3MH is ignored if Timer 3 is in any other mode.
0: Timer 3 high byte uses the clock defined by the T3XCLK bit in TMR3CN.
1: Timer 3 high byte uses the system clock.
T3ML: Timer 3 Low Byte Clock Select.
This bit selects the clock supplied to Timer 3. If Timer 3 is configured in split 8-bit timer
mode, this bit selects the clock supplied to the lower 8-bit timer.
0: Timer 3 low byte uses the clock defined by the T3XCLK bit in TMR3CN.
1: Timer 3 low byte uses the system clock.
T2MH: Timer 2 High Byte Clock Select.
This bit selects the clock supplied to the Timer 2 high byte if Timer 2 is configured in split 8-
bit timer mode. T2MH is ignored if Timer 2 is in any other mode.
0: Timer 2 high byte uses the clock defined by the T2XCLK bit in TMR2CN.
1: Timer 2 high byte uses the system clock.
T2ML: Timer 2 Low Byte Clock Select.
This bit selects the clock supplied to Timer 2. If Timer 2 is configured in split 8-bit timer
mode, this bit selects the clock supplied to the lower 8-bit timer.
0: Timer 2 low byte uses the clock defined by the T2XCLK bit in TMR2CN.
1: Timer 2 low byte uses the system clock.
T1M: Timer 1 Clock Select.
This select the clock source supplied to Timer 1. T1M is ignored when C/T1 is set to logic 1.
0: Timer 1 uses the clock defined by the prescale bits, SCA1-SCA0.
1: Timer 1 uses the system clock.
T0M: Timer 0 Clock Select.
This bit selects the clock source supplied to Timer 0. T0M is ignored when C/T0 is set to
logic 1.
0: Counter/Timer 0 uses the clock defined by the prescale bits, SCA1-SCA0.
1: Counter/Timer 0 uses the system clock.
These bits control the division of the clock supplied to Timer 0 and/or Timer 1 if configured
to use prescaled clock inputs.
Note: External clock divided by 8 is synchronized with the system clock, and the external
T3ML
R/W
SCA1
Bit6
clock must be less than or equal to the system clock to operate in this mode.
0
0
1
1
T2MH
R/W
Bit5
SCA0
0
1
0
1
T2ML
R/W
Bit4
Rev. 0.3
T1M
R/W
Bit3
System clock divided by 12
System clock divided by 48
External clock divided by 8
System clock divided by 4
T0M
Prescaled Clock
R/W
Bit2
SCA1
R/W
Bit1
SCA0
R/W
Bit0
SFR Address:
00000000
Reset Value
0x8E