mc9s12xs128 Freescale Semiconductor, Inc, mc9s12xs128 Datasheet - Page 283

no-image

mc9s12xs128

Manufacturer Part Number
mc9s12xs128
Description
Hcs12 Microcontrollers 16-bit Automotive Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s12xs128CAA
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s12xs128CAA
Quantity:
37
Part Number:
mc9s12xs128CAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
3 050
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
3 050
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
4 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
5 630
Part Number:
mc9s12xs128MAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAA
0
Part Number:
mc9s12xs128MAA 1M04M
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAE
Manufacturer:
INITIO
Quantity:
3 310
Part Number:
mc9s12xs128MAL
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s12xs128VAA
Quantity:
58
10.3.2.6
Writes to this register will abort current conversion sequence and start a new conversion sequence. If
external trigger is enabled (ETRIGE=1) an initial write to ATDCTL5 is required to allow starting of a
conversion sequence which will then occur on each trigger event. Start of conversion means the beginning
of the sampling phase.
Read: Anytime
Write: Anytime
Freescale Semiconductor
Module Base + 0x0005
Reset
SCAN
Field
SC
6
5
W
R
Special Channel Conversion Bit — If this bit is set, then special channel conversion can be selected using CD,
CC, CB and CA of ATDCTL5.
0 Special channel conversions disabled
1 Special channel conversions enabled
Continuous Conversion Sequence Mode — This bit selects whether conversion sequences are performed
continuously or only once. If external trigger is enabled (ETRIGE=1) setting this bit has no effect, that means
external trigger always starts a single conversion sequence.
0 Single conversion sequence
1 Continuous conversion sequences (scan mode)
ATD Control Register 5 (ATDCTL5)
0
0
7
SMP2
SC
0
6
1
Figure 10-8. ATD Control Register 5 (ATDCTL5)
Table 10-14. ATDCTL5 Field Descriptions
S12XS Family Reference Manual, Rev. 1.10
SMP1
SCAN
Table 10-13. Sample Time Select
Table 10-15
1
0
5
SMP0
lists the coding.
MULT
1
0
4
Description
ATD Clock Cycles
CD
0
3
Sample Time
in Number of
24
Analog-to-Digital Converter (ADC12B16CV1)
CC
0
2
CB
0
1
CA
0
0
283