xr16m890 Exar Corporation, xr16m890 Datasheet - Page 38

no-image

xr16m890

Manufacturer Part Number
xr16m890
Description
Uart With 128-byte Fifo And Integrated Level Shifters
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16m890IL32-F
Manufacturer:
EXAR
Quantity:
1 420
Part Number:
xr16m890IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16m890IL40-F
Quantity:
700
Company:
Part Number:
xr16m890IL40-F
Quantity:
3 300
Part Number:
xr16m890IM48-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr16m890IM48-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16m890IM48-F
Quantity:
412
Part Number:
xr16m890IM48TR-F
Manufacturer:
Exar Corporation
Quantity:
10 000
XR16M890
UART WITH 128-BYTE FIFO AND INTEGRATED LEVEL SHIFTERS
MCR[4]: Internal Loopback Enable
MCR[5]: Xon-Any Enable (requires EFR bit-4 = 1)
MCR[6]: Infrared Encoder/Decoder Enable (requires EFR bit-4 = 1)
MCR[7]: Clock Prescaler Select (requires EFR bit-4 = 1)
This register provides the status of data transfers between the UART and the host. If IER bit-2 is enabled, LSR
bit 1 will generate an interrupt immediately and LSR bits 2-4 will generate an interrupt when a character with an
error is in the RHR.
LSR[0]: Receive Data Ready Indicator
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Tag
LSR[3]: Receive Data Framing Error Tag
3.8
Logic 0 = Disable loopback mode (default).
Logic 1 = Enable local loopback mode, see loopback section and
Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO , unless the RX character is an Xon or Xoff character and
the M890 is programmed to use the Xon/Xoff flow control.
Logic 0 = Enable the standard modem receive and transmit input/output interface. (Default)
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. The RX FIFO may need to be flushed upon enable. While in this mode, the infrared TX output
will be LOW during idle data conditions.
Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
Line Status Register (LSR) - Read Only
PRELIMINARY
38
Figure
17.
REV. P1.1.1

Related parts for xr16m890