EVAL-ADE7816EBZ AD [Analog Devices], EVAL-ADE7816EBZ Datasheet - Page 16

no-image

EVAL-ADE7816EBZ

Manufacturer Part Number
EVAL-ADE7816EBZ
Description
Six Current Channels, One Voltage Channel
Manufacturer
AD [Analog Devices]
Datasheet
ADE7816
QUICK START
This section outlines the procedure for powering up and initializing
the ADE7816. Figure 23 shows a flow diagram of the initialization
steps. For detailed information, refer to the section of the data
sheet that pertains to each step, as indicated in Figure 23.
Table 8. Required Register Defaults
Register
Address
0x43AB
0x43AC
0x43AD
0x43AE
0x43B1
0x43B2
0x43B3
0x43B4
0x43B5
0x43B6
0x4388
Register
Name
WTHR1
WTHR0
VARTHR1
VARTHR0
PCF_A_COEFF
PCF_B_COEFF
PCF_C_COEFF
PCF_D_COEFF
PCF_E_COEFF
PCF_F_COEFF
DICOEFF
Register Description
Threshold register for active energy
Threshold register for active energy
Threshold register for reactive energy
Threshold register for reactive energy
Phase calibration for Current Channel A
Phase calibration for Current Channel B
Phase calibration for Current Channel C
Phase calibration for Current Channel D
Phase calibration for Current Channel E
Phase calibration for Current Channel F
Digital integrator algorithm; required only
if using di/dt sensors
WTHR1 = 0x000002
WTHR0 = 0x000000
VARTHR1 = 0x000002
VARTHR0 = 0x000000
PCF_A_COEFF = 0x400CA4 (50Hz)
PCF_B_COEFF = 0x400CA4 (50Hz)
PCF_C_COEFF = 0x400CA4 (50Hz)
PCF_D_COEFF = 0x400CA4 (50Hz)
PCF_E_COEFF = 0x400CA4 (50Hz)
PCF_F_COEFF = 0x400CA4 (50Hz)
DICOEFF = 0xFFF8000
Figure 23. Quick Start
Rev. 0 | Page 16 of 48
FEATURES, AND ENERGY
CALIBRATION SECTIONS)
COMMUNICATION MODE
SPECIFIC INTERRUPTS,
(SEE THE INTERRUPTS,
(SEE COMMUNICATION
ENABLE THE ENERGY
(SEE STARTING AND
CONFIGURE METER
STOPPING THE DSP
GROUND SECTION)
(SEE POWER AND
WRITE REQUIRED
POWER QUALITY
POWER QUALITY
FEATURES, AND
POWER UP THE
SET AND LOCK
METERING DSP
INITIALIZATION
CALIBRATE
Required Value
0x000002
0x000000
0x000002
0x000000
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0xFFF8000
COMPLETE
DEFAULTS
REGISTER
SECTION)
SECTION)
ADE7816
After power is supplied to the
is established, a set of registers must be written (see Figure 23).
Table 8 lists details about each register.
The registers listed in Table 8 are essential for correct operation.
After these registers are set, enable any meter-specific features
before enabling the DSP to begin the energy calculations.
NOTE THAT THE FINAL
REGISTER SHOULD BE
WRITTEN 3 TIMES TO
CLEAR THE BUFFER
(SEE STARTING AND
STOPPING THE DSP
SECTION)
Reference Information
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Refer to the
Active Energy Threshold
Active Energy Threshold
Reactive Energy Threshold
Reactive Energy Threshold
Energy Phase Calibration
Energy Phase Calibration
Energy Phase Calibration
Energy Phase Calibration
Energy Phase Calibration
Energy Phase Calibration
Digital Integrator
ADE7816
and communication
section.
Data Sheet
section.
section.
section.
section.
section.
section.
section.
section.
section.
section.